CXGwMux-MIB :: gmfSRFailStatus

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCXGwMux-MIBgmfSRFailStatus

gmfSRFailStatus

Module: CXGwMux-MIB

OID (symbolic): CXGwMux-MIB::gmfSRFailStatus

OID (numeric): 1.3.6.1.4.1.495.2.1.6.5.4.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Indicates the reason for a connection failure on a system route prior to the next attempt to establish a connection on that route.

Default Value: none

Options: noFailure (1): did not fail

internalError (2): system error

localMemAllocFailure (3): GMF memory allocation error

remoteMemAllocFailure (4): FRIM memory allocation error

remoteNoAccess (5): FRIM not configured

remotePvcDown (6): FRIM reported down

remotevcBusy (7): FRIM busy

localFcnFailure (8): flow control type unknown to GMF

remoteFcnFailure (9): flow control type unknown to FRIM

localDsnFailure (10): GMF could not negotiate data size

remoteAliasNotFound (11): no PVC for destination alias

remoteNoPvcService (12): FRIM not supporting PVC protocol

openReqTimeout (13): timeout of open connection request

adjaCardReset (14): adjacent CPU reset (CX 1000 only)

linkNotSupported (15): system route number not supported

What is gmfSRFailStatus?

This reports the specific reason a system route's connection attempt failed, such as remotePvcDown, remoteAliasNotFound, openReqTimeout, or adjaCardReset (CX1000 only). An admin reads this value to diagnose exactly why a route in gmfSRConStatus failed to open, rather than just knowing that it failed.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.5.4.1.5
snmpwalk -v2c -c public <target> CXGwMux-MIB::gmfSRFailStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.5.4.1.5.1
snmpget -v2c -c public <target> CXGwMux-MIB::gmfSRFailStatus.1

Start monitoring Aastra ConvertedX (CX) gateway/multiplexer (voice/data mux) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CXGwMux-MIB::gmfSRFailStatus OID value, configure state conditions and alerts, and monitor any Aastra ConvertedX (CX) gateway/multiplexer (voice/data mux) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.495memotecMEMOTEC-SMI
1.3.6.1.4.1.495.2memotecProductsMEMOTEC-SMI
1.3.6.1.4.1.495.2.1cxProductMEMOTEC-SMI
1.3.6.1.4.1.495.2.1.6cxApplicationCXProduct-SMI
1.3.6.1.4.1.495.2.1.6.5cxGwMuxCXProduct-SMI
Numeric OIDNameModule
1.3.6.1.4.1.495.2.1.6.5.4gmfSRTableCXGwMux-MIB
1.3.6.1.4.1.495.2.1.6.5.4.1gmfSREntryCXGwMux-MIB
1.3.6.1.4.1.495.2.1.6.5.4.1.5gmfSRFailStatusCXGwMux-MIB