CXFrameRelayInterfaceModule-MIB :: frimSapstatSRUnsuccessfulConnects

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CXFrameRelayInterfaceModule-MIB › frimSapstatSRUnsuccessfulConnects

frimSapstatSRUnsuccessfulConnects

Module: CXFrameRelayInterfaceModule-MIB

OID (symbolic): CXFrameRelayInterfaceModule-MIB::frimSapstatSRUnsuccessfulConnects

OID (numeric): 1.3.6.1.4.1.495.2.1.6.2.3.1.29

Node type: OBJECT-TYPE

Type: Counter

Access: read-only

Description: Indicates the number of times the FRIM software layer attempted but failed to establish a system route connection between two Frame Relay service providers. This object is meaningful only if 'frimSapType' for this SAP is set to 'upper'.

Range of Values: 0 - 4, 294, 967, 295

Default Value: none

What is frimSapstatSRUnsuccessfulConnects?

On an upper-type SAP, a 32-bit counter of failed attempts to establish a system route connection between two Frame Relay service providers. An admin correlates a rising count here with frimSRClearStatus on the relevant route to find the root cause.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.2.3.1.29
snmpwalk -v2c -c public <target> CXFrameRelayInterfaceModule-MIB::frimSapstatSRUnsuccessfulConnects

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.2.3.1.29.1
snmpget -v2c -c public <target> CXFrameRelayInterfaceModule-MIB::frimSapstatSRUnsuccessfulConnects.1

Start monitoring Legacy Crosscomm CX900/CX1000 router (Frame Relay SAP) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CXFrameRelayInterfaceModule-MIB::frimSapstatSRUnsuccessfulConnects OID value, configure state conditions and alerts, and monitor any Legacy Crosscomm CX900/CX1000 router (Frame Relay SAP) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.495memotecMEMOTEC-SMI
1.3.6.1.4.1.495.2memotecProductsMEMOTEC-SMI
1.3.6.1.4.1.495.2.1cxProductMEMOTEC-SMI
1.3.6.1.4.1.495.2.1.6cxApplicationCXProduct-SMI
1.3.6.1.4.1.495.2.1.6.2cxFrameRelayInterfaceModuleCXProduct-SMI
Numeric OIDNameModule
1.3.6.1.4.1.495.2.1.6.2.3frimSapTableCXFrameRelayInterfaceModule-MIB
1.3.6.1.4.1.495.2.1.6.2.3.1frimSapEntryCXFrameRelayInterfaceModule-MIB
1.3.6.1.4.1.495.2.1.6.2.3.1.29frimSapstatSRUnsuccessfulConnectsCXFrameRelayInterfaceModule-MIB