CXFrameRelayInterfaceModule-MIB :: frimSRClearStatus

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CXFrameRelayInterfaceModule-MIB › frimSRClearStatus

frimSRClearStatus

Module: CXFrameRelayInterfaceModule-MIB

OID (symbolic): CXFrameRelayInterfaceModule-MIB::frimSRClearStatus

OID (numeric): 1.3.6.1.4.1.495.2.1.6.2.6.1.16

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Indicates the reason for a connection failure on the system route. This status is meaningful only between attempts to establish a system route. Successive failed attempts may or may not change the displayed value.

Options: noFailure (1): no failure (connection has occurred)

internalError (2): internal system error

localAllocFailure (3): not enough memory in local device to establish system route at current time

remoteAllocFailure (4): not enough memory in remote device to establish system route at current time

localNoAccess (5): PVC in local device not configured

remoteNoAccess (6): PVC in remote dcevice not configured

localPvcDown (7): PVC in local device reported down

remotePvcDown (8): PVC in remote device reported down

localPvcBusy (9): PVC in local device is busy (PVC is SPE or PVC is MPE but 'frimSRSubRef' is in use)

remotePvcBusy (10): PVC in remote device is busy (PVC is SPE or PVC is MPE but 'frimSRSubRef' is in use)

localFcnFailure (11): local device does not support flow control type

remoteFcnFailure (12): remote device does not support flow control type

localDsnFailure (13): local device could not negotiate size of data unit because remote's maximum data unit was zero

localRefInUse (14): 'frimSRSubRef' in use in local device

remoteAliasNotFound (15): no PVC in the local device has this destination alias

remoteNoPvcService (16): remote device does not support PVCs

Default Value: none

What is frimSRClearStatus?

Reports the specific reason (from 16 enumerated causes such as localPvcDown, remoteAllocFailure, or localRefInUse) that a system route connection attempt failed, meaningful only between connection attempts. An admin reads this value when frimSRRouteStatus shows notConnected to diagnose why the route won't come up.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.2.6.1.16
snmpwalk -v2c -c public <target> CXFrameRelayInterfaceModule-MIB::frimSRClearStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.2.6.1.16.1
snmpget -v2c -c public <target> CXFrameRelayInterfaceModule-MIB::frimSRClearStatus.1

Start monitoring Legacy Crosscomm CX900/CX1000 router (Frame Relay SAP) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CXFrameRelayInterfaceModule-MIB::frimSRClearStatus OID value, configure state conditions and alerts, and monitor any Legacy Crosscomm CX900/CX1000 router (Frame Relay SAP) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.495memotecMEMOTEC-SMI
1.3.6.1.4.1.495.2memotecProductsMEMOTEC-SMI
1.3.6.1.4.1.495.2.1cxProductMEMOTEC-SMI
1.3.6.1.4.1.495.2.1.6cxApplicationCXProduct-SMI
1.3.6.1.4.1.495.2.1.6.2cxFrameRelayInterfaceModuleCXProduct-SMI
Numeric OIDNameModule
1.3.6.1.4.1.495.2.1.6.2.6frimSRTableCXFrameRelayInterfaceModule-MIB
1.3.6.1.4.1.495.2.1.6.2.6.1frimSREntryCXFrameRelayInterfaceModule-MIB
1.3.6.1.4.1.495.2.1.6.2.6.1.16frimSRClearStatusCXFrameRelayInterfaceModule-MIB