All MIBs › CXBsc-MIB › bscCuPollTimeout
bscCuPollTimeout
Module: CXBsc-MIB
OID (symbolic): CXBsc-MIB::bscCuPollTimeout
OID (numeric): 1.3.6.1.4.1.495.2.1.6.56.11.1.6
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Identifies the number of seconds a station waits for an answer. The value is measured in tenth of seconds.
What is bscCuPollTimeout?
This read-write value, in tenths of a second (1-250, default 30), sets how long the module waits for a controller unit to answer a poll before treating it as a timeout. An admin lengthens this for slower or more distant controller units that are otherwise showing up in bscDevErrTimeout too often.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.56.11.1.6 snmpwalk -v2c -c public <target> CXBsc-MIB::bscCuPollTimeout
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.56.11.1.6.1 snmpget -v2c -c public <target> CXBsc-MIB::bscCuPollTimeout.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.495.2.1.6.56.11.1.6.1 i <value>
Start monitoring Memotec CX BSC/SNA protocol converter with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CXBsc-MIB::bscCuPollTimeout OID value, configure state conditions and alerts, and monitor any Memotec CX BSC/SNA protocol converter from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.495 | memotec | MEMOTEC-SMI |
| 1.3.6.1.4.1.495.2 | memotecProducts | MEMOTEC-SMI |
| 1.3.6.1.4.1.495.2.1 | cxProduct | MEMOTEC-SMI |
| 1.3.6.1.4.1.495.2.1.6 | cxApplication | CXProduct-SMI |
| 1.3.6.1.4.1.495.2.1.6.56 | cxBsc | CXProduct-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.495.2.1.6.56.11 | bscCuTable | CXBsc-MIB |
| 1.3.6.1.4.1.495.2.1.6.56.11.1 | bscCuEntry | CXBsc-MIB |
| 1.3.6.1.4.1.495.2.1.6.56.11.1.6 | bscCuPollTimeout | CXBsc-MIB |