CXAtmPhy-MIB :: atmPhyConfPlcpControl

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CXAtmPhy-MIB › atmPhyConfPlcpControl

atmPhyConfPlcpControl

Module: CXAtmPhy-MIB

OID (symbolic): CXAtmPhy-MIB::atmPhyConfPlcpControl

OID (numeric): 1.3.6.1.4.1.495.2.1.6.61.10.1.45

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Defines the PLCP error generation controls permitted at this interface. This object is bit-mapped and can permit a maximum of 8 simultaneous error controls. Once the controls are initiated, the selected errors are generated for a period of time specified by object 'atmPhyConfPlcpControlTimer'. Error generation can be restarted at any time.

To enable a specific control, its bit must be set. To disable a specific control, its bit must be reset. The controls are assigned the following bits:

(bit-0): Controls the generation of a PLCP yellow alarm signal by setting the yellow signal bit position in the path status octet (G1) within consecutive PLCP frames.

(bit-1): Controls the generation of a PLCP Far End Block Errors (FEBE) by inserting a single far end block error within consecutive PLCP frames.

(bit-2): Controls the generation of PLCP Bit Interleave Parity (BIP) errors by inserting a single bit interleave parity error within consecutive PLCP frames.

(bit-3): Controls the generation of frame alignment pattern errors by inserting a single bit error in each A1 & A2 octets within consecutive PLCP frames.

(bit-4): Controls the generation of parity errors by inserting a parity error into each path overhead identification (POHID) octet within consecutive PLCP frames.

What is atmPhyConfPlcpControl?

A read-write, bit-mapped INTEGER (0-255, default 0) that enables up to five simultaneous PLCP error-injection tests on this interface (e.g. bit-0 forces a yellow alarm, bit-1 forces a FEBE error, bit-2 a BIP error) for the duration set by atmPhyConfPlcpControlTimer, used to validate a peer's error-detection handling.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.61.10.1.45
snmpwalk -v2c -c public <target> CXAtmPhy-MIB::atmPhyConfPlcpControl

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.61.10.1.45.1
snmpget -v2c -c public <target> CXAtmPhy-MIB::atmPhyConfPlcpControl.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.495.2.1.6.61.10.1.45.1 i <value>

Start monitoring CX Memotec ATM access/gateway device (physical layer) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CXAtmPhy-MIB::atmPhyConfPlcpControl OID value, configure state conditions and alerts, and monitor any CX Memotec ATM access/gateway device (physical layer) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.495memotecMEMOTEC-SMI
1.3.6.1.4.1.495.2memotecProductsMEMOTEC-SMI
1.3.6.1.4.1.495.2.1cxProductMEMOTEC-SMI
1.3.6.1.4.1.495.2.1.6cxApplicationCXProduct-SMI
1.3.6.1.4.1.495.2.1.6.61cxAtmPhyCXProduct-SMI
Numeric OIDNameModule
1.3.6.1.4.1.495.2.1.6.61.10atmPhyInterfaceConfTableCXAtmPhy-MIB
1.3.6.1.4.1.495.2.1.6.61.10.1atmPhyInterfaceConfEntryCXAtmPhy-MIB
1.3.6.1.4.1.495.2.1.6.61.10.1.45atmPhyConfPlcpControlCXAtmPhy-MIB