CTRON-PRIORITY-CLASSIFY-MIB :: ctPriClassifyRowStatus

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-PRIORITY-CLASSIFY-MIB › ctPriClassifyRowStatus

ctPriClassifyRowStatus

Module: CTRON-PRIORITY-CLASSIFY-MIB

OID (symbolic): CTRON-PRIORITY-CLASSIFY-MIB::ctPriClassifyRowStatus

OID (numeric): 1.3.6.1.4.1.52.4.1.2.14.6.1.4.1.6

Node type: OBJECT-TYPE

Type: RowStatus

Access: read-create

Description: This object provides both control and status for the associated conceptual row in the table. Rows can be created in two ways.

createAndGo - The specified row will be created and activated if the instance is allowable. If not, an inconsistentValue exception will be returned and the row will not be created. This provides the most optimal method of creating an active row, but provides the user no explanation if the row cannot be created.

createAndWait - The specified row will be created and put in the notInService state if the instance is allowable. A subsequent activation of this row will bring it into the active state. If the instance is not allowable, the row will be created and put in the notReady state. A subsequent activation of this row will fail. Since the inappropriate information is always contained in the indexing leaves, activation will never succeed and the row should be removed by the management station. When a row is in the notReady state, the ctPriClassifyRowInfo may be retrieved to obtain a plain English explanation of why this row cannot be activated. createAndWait is the preferred method for this reason.

Both methods described above leave ctPriClassifyIngressList in it's default state, requiring an additional set operation in order to modify it. An even more optimal twist on the createAndWait method is to set the ctPriClassifyIngressList to it's desired value as a method for row creation. This will essentially cause an implicit createAndWait since it too will leave the row in either the notInService or notReady state. This leaves only activation or error analysis as the last step.

Any rows left in the notReady or notInService state for more than 5 minutes should be automatically removed by the agent implementation.

What is ctPriClassifyRowStatus?

This is the standard RowStatus control for creating, activating, or deleting a classification rule row, with the source description noting createAndWait as the preferred creation method since it allows the agent to explain via ctPriClassifyRowInfo why a row is stuck in notReady state, and any row left notReady or notInService for over 5 minutes should be auto-removed. Admins use createAndWait when provisioning a new classification rule, then set ctPriClassifyIngressList and other columns before activating it. For example, an admin creates a rule with createAndWait, configures its ingress ports and match criteria, then sets ctPriClassifyRowStatus to active(1) to bring the rule online.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.1ctronCTRON-ISDN-CONFIGURATION-MIB
1.3.6.1.4.1.52.4.1.2ctDataLinkCTRON-ISDN-CONFIGURATION-MIB
1.3.6.1.4.1.52.4.1.2.14ctPriorityExtCTRON-MIB-NAMES
Numeric OIDNameModule
1.3.6.1.4.1.52.4.1.2.14.6ctPriClassifyCTRON-PRIORITY-CLASSIFY-MIB
1.3.6.1.4.1.52.4.1.2.14.6.1ctPriClassifyObjectsCTRON-PRIORITY-CLASSIFY-MIB
1.3.6.1.4.1.52.4.1.2.14.6.1.4ctPriClassifyTableCTRON-PRIORITY-CLASSIFY-MIB
1.3.6.1.4.1.52.4.1.2.14.6.1.4.1ctPriClassifyEntryCTRON-PRIORITY-CLASSIFY-MIB
1.3.6.1.4.1.52.4.1.2.14.6.1.4.1.6ctPriClassifyRowStatusCTRON-PRIORITY-CLASSIFY-MIB