All MIBs › CTRON-IPX-ROUTER-MIB › nwIpxSapHoldDown
nwIpxSapHoldDown
Module: CTRON-IPX-ROUTER-MIB
OID (symbolic): CTRON-IPX-ROUTER-MIB::nwIpxSapHoldDown
OID (numeric): 1.3.6.1.4.1.52.4.2.2.2.3.2.2.4.1.2.1.1.10
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Specifies the amount of time, in seconds, to wait before removing an entry from the SAP server table, after receiving an update indicating that the destination has become unreachable. All routers exchanging SAP information must have the same hold down time. The time must be long enough to allow all participating routers to receive the same update.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.2.2.3.2.2.4.1.2.1.1.10 snmpwalk -v2c -c public <target> CTRON-IPX-ROUTER-MIB::nwIpxSapHoldDown
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.2.2.3.2.2.4.1.2.1.1.10.1 snmpget -v2c -c public <target> CTRON-IPX-ROUTER-MIB::nwIpxSapHoldDown.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.2.2.2.3.2.2.4.1.2.1.1.10.1 i <value>
Start monitoring Cabletron/Enterasys router (legacy Novell IPX) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-IPX-ROUTER-MIB::nwIpxSapHoldDown OID value, configure state conditions and alerts, and monitor any Cabletron/Enterasys router (legacy Novell IPX) from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2 | ctronExp | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2.2 | ctronRouterExp | ROUTER-OIDS |
| 1.3.6.1.4.1.52.4.2.2.2 | nwRouter | ROUTER-OIDS |
| 1.3.6.1.4.1.52.4.2.2.2.3 | nwRtrProtoSuites | ROUTER-OIDS |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.2.2.2.3.2 | nwIpxRouter | CTRON-IPX-ROUTER-MIB |
| 1.3.6.1.4.1.52.4.2.2.2.3.2.2 | nwIpxComponents | CTRON-IPX-ROUTER-MIB |
| 1.3.6.1.4.1.52.4.2.2.2.3.2.2.4 | nwIpxTopology | CTRON-IPX-ROUTER-MIB |
| 1.3.6.1.4.1.52.4.2.2.2.3.2.2.4.1 | nwIpxDistanceVector | CTRON-IPX-ROUTER-MIB |
| 1.3.6.1.4.1.52.4.2.2.2.3.2.2.4.1.2 | nwIpxSap | CTRON-IPX-ROUTER-MIB |
| 1.3.6.1.4.1.52.4.2.2.2.3.2.2.4.1.2.1 | nwIpxSapSystem | CTRON-IPX-ROUTER-MIB |
| 1.3.6.1.4.1.52.4.2.2.2.3.2.2.4.1.2.1.1 | nwIpxSapConfig | CTRON-IPX-ROUTER-MIB |
| 1.3.6.1.4.1.52.4.2.2.2.3.2.2.4.1.2.1.1.10 | nwIpxSapHoldDown | CTRON-IPX-ROUTER-MIB |