CTRON-IPX-ROUTER-MIB :: nwIpxFwdIfCacheControl

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-IPX-ROUTER-MIB › nwIpxFwdIfCacheControl

nwIpxFwdIfCacheControl

Module: CTRON-IPX-ROUTER-MIB

OID (symbolic): CTRON-IPX-ROUTER-MIB::nwIpxFwdIfCacheControl

OID (numeric): 1.3.6.1.4.1.52.4.2.2.2.3.2.2.2.2.1.1.1.11

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Controls IPX Address caching on the router port for which the entry exists. When IPX Address caching is enabled, IPX Addresses used for address validation, filtering, and forwarding are stored in the cache. This cache is checked first before doing a full route table lookup, which speeds up the switching process. Enabled (3) turns on IPX Address caching. Disabled (2) turns it off.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.2.2.3.2.2.2.2.1.1.1.11
snmpwalk -v2c -c public <target> CTRON-IPX-ROUTER-MIB::nwIpxFwdIfCacheControl

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.2.2.3.2.2.2.2.1.1.1.11.1
snmpget -v2c -c public <target> CTRON-IPX-ROUTER-MIB::nwIpxFwdIfCacheControl.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.2.2.2.3.2.2.2.2.1.1.1.11.1 i <value>

Start monitoring Cabletron/Enterasys router (legacy Novell IPX) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-IPX-ROUTER-MIB::nwIpxFwdIfCacheControl OID value, configure state conditions and alerts, and monitor any Cabletron/Enterasys router (legacy Novell IPX) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2ctronExpCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.2ctronRouterExpROUTER-OIDS
1.3.6.1.4.1.52.4.2.2.2nwRouterROUTER-OIDS
1.3.6.1.4.1.52.4.2.2.2.3nwRtrProtoSuitesROUTER-OIDS
Numeric OIDNameModule
1.3.6.1.4.1.52.4.2.2.2.3.2nwIpxRouterCTRON-IPX-ROUTER-MIB
1.3.6.1.4.1.52.4.2.2.2.3.2.2nwIpxComponentsCTRON-IPX-ROUTER-MIB
1.3.6.1.4.1.52.4.2.2.2.3.2.2.2nwIpxForwardingCTRON-IPX-ROUTER-MIB
1.3.6.1.4.1.52.4.2.2.2.3.2.2.2.2nwIpxFwdInterfacesCTRON-IPX-ROUTER-MIB
1.3.6.1.4.1.52.4.2.2.2.3.2.2.2.2.1nwIpxFwdIfConfigCTRON-IPX-ROUTER-MIB
1.3.6.1.4.1.52.4.2.2.2.3.2.2.2.2.1.1nwIpxFwdIfTableCTRON-IPX-ROUTER-MIB
1.3.6.1.4.1.52.4.2.2.2.3.2.2.2.2.1.1.1nwIpxFwdIfEntryCTRON-IPX-ROUTER-MIB
1.3.6.1.4.1.52.4.2.2.2.3.2.2.2.2.1.1.1.11nwIpxFwdIfCacheControlCTRON-IPX-ROUTER-MIB