nwDecIVEventFltrSeverity
Module: CTRON-DECIV-ROUTER-MIB
OID (symbolic): CTRON-DECIV-ROUTER-MIB::nwDecIVEventFltrSeverity
OID (numeric): 1.3.6.1.4.1.52.4.2.2.2.3.3.2.10.2.1.1.5
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Specifies the level of severity an event must meet in order to be logged. Controls the amount of event logging by ignoring events of a lower priority than specified by this filter value. `Highmed' ignores only events of the lowest severity. `Highlow' logs all events highest priority through lowest. `Highest' severity causes all events except those of the highest severity to be ignored. `Highmed' severity is the default setting which causes only events of the lowest severity to be ignored. `Highlow' severity logs all events, regardless of severity.
What is nwDecIVEventFltrSeverity?
nwDecIVEventFltrSeverity specifies the minimum level of severity an event must meet to be logged by this filter, where highest ignores all but the highest-severity events, highlow logs everything from highest through lowest severity, and highmed, the default, ignores only the very lowest-severity events. An admin sets this to control how much event volume a given filter lets through, tuning it toward highlow for maximum visibility or highest to see only the most critical events. For example, an admin who only wants to be alerted to the most serious DECnet problems on a given port would set that filter's nwDecIVEventFltrSeverity to highest, suppressing lower-priority noise.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.2.2.3.3.2.10.2.1.1.5 snmpwalk -v2c -c public <target> CTRON-DECIV-ROUTER-MIB::nwDecIVEventFltrSeverity
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.2.2.3.3.2.10.2.1.1.5.1 snmpget -v2c -c public <target> CTRON-DECIV-ROUTER-MIB::nwDecIVEventFltrSeverity.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.2.2.2.3.3.2.10.2.1.1.5.1 i <value>
Start monitoring Cabletron router/multiprotocol switch (legacy DECnet Phase IV) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-DECIV-ROUTER-MIB::nwDecIVEventFltrSeverity OID value, configure state conditions and alerts, and monitor any Cabletron router/multiprotocol switch (legacy DECnet Phase IV) from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CTRON-AP3000-MIB |
| 1.3.6.1.4.1.52.4.2 | ctronExp | CTRON-MIB-NAMES |
| 1.3.6.1.4.1.52.4.2.2 | ctronRouterExp | ROUTER-OIDS |
| 1.3.6.1.4.1.52.4.2.2.2 | nwRouter | ROUTER-OIDS |
| 1.3.6.1.4.1.52.4.2.2.2.3 | nwRtrProtoSuites | ROUTER-OIDS |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.2.2.2.3.3 | nwDecIVRouter | CTRON-DECIV-ROUTER-MIB |
| 1.3.6.1.4.1.52.4.2.2.2.3.3.2 | nwDecIVComponents | CTRON-DECIV-ROUTER-MIB |
| 1.3.6.1.4.1.52.4.2.2.2.3.3.2.10 | nwDecIVEvent | CTRON-DECIV-ROUTER-MIB |
| 1.3.6.1.4.1.52.4.2.2.2.3.3.2.10.2 | nwDecIVEventLogFilterTable | CTRON-DECIV-ROUTER-MIB |
| 1.3.6.1.4.1.52.4.2.2.2.3.3.2.10.2.1 | nwDecIVEventFilterTable | CTRON-DECIV-ROUTER-MIB |
| 1.3.6.1.4.1.52.4.2.2.2.3.3.2.10.2.1.1 | nwDecIVEventFilterEntry | CTRON-DECIV-ROUTER-MIB |
| 1.3.6.1.4.1.52.4.2.2.2.3.3.2.10.2.1.1.5 | nwDecIVEventFltrSeverity | CTRON-DECIV-ROUTER-MIB |