CTRON-CSMACD-MIB :: ctFnbConnect

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-CSMACD-MIB › ctFnbConnect

ctFnbConnect

Module: CTRON-CSMACD-MIB

OID (symbolic): CTRON-CSMACD-MIB::ctFnbConnect

OID (numeric): 1.3.6.1.4.1.52.4.1.2.4.1.1.1.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Denotes the connection status of the CSMA/CD board to the inter-RIC bus. The values of 1, 2, and 4 define connection status of connect for the subsystem, values 5 and 6 define connection status of subnet connect for the subsystem, value 8 is defined as a front panel connection on the module, and a value of 3 defines disconnect status.

What is ctFnbConnect?

ctFnbConnect is a read-write enumerated value that reports, and lets an admin set, how this CSMA/CD board is physically wired into the chassis's inter-RIC backplane bus. Because the coded values group into "connect" (1, 2, 4), "subnet connect" (5, 6), a front-panel connection (8), or disconnect (3), an admin can see at a glance whether the board is bridged onto a backplane channel, only reachable via its front panel, or cut off entirely. For instance, seeing ctFnbConnect return disconnect(3) on a board that is supposed to be forwarding traffic tells the admin that board's inter-RIC bus link has been dropped and needs to be reconnected.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.1.2.4.1.1.1.1.2
snmpwalk -v2c -c public <target> CTRON-CSMACD-MIB::ctFnbConnect

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.1.2.4.1.1.1.1.2.1
snmpget -v2c -c public <target> CTRON-CSMACD-MIB::ctFnbConnect.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.1.2.4.1.1.1.1.2.1 i <value>

Start monitoring Cabletron/Enterasys Ethernet switch or hub (CSMA/CD interface stats) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-CSMACD-MIB::ctFnbConnect OID value, configure state conditions and alerts, and monitor any Cabletron/Enterasys Ethernet switch or hub (CSMA/CD interface stats) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.1ctronCTRON-MIB-NAMES
1.3.6.1.4.1.52.4.1.2ctDataLinkCTRON-MIB-NAMES
1.3.6.1.4.1.52.4.1.2.4ctEthernetCTRON-MIB-NAMES
1.3.6.1.4.1.52.4.1.2.4.1ctCSMACDCTRON-MIB-NAMES
Numeric OIDNameModule
1.3.6.1.4.1.52.4.1.2.4.1.1ctFnbCSMACDCTRON-CSMACD-MIB
1.3.6.1.4.1.52.4.1.2.4.1.1.1ctFnbCSMACDTableCTRON-CSMACD-MIB
1.3.6.1.4.1.52.4.1.2.4.1.1.1.1ctFnbCSMACDEntryCTRON-CSMACD-MIB
1.3.6.1.4.1.52.4.1.2.4.1.1.1.1.2ctFnbConnectCTRON-CSMACD-MIB