CTRON-COMMON-MIB :: upsDisconnect

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCTRON-COMMON-MIBupsDisconnect

upsDisconnect

Module: CTRON-COMMON-MIB

OID (symbolic): CTRON-COMMON-MIB::upsDisconnect

OID (numeric): 1.3.6.1.4.1.52.1.6.3.1.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Allows the UPS backup power system to conserve its battery. Setting the object to a value of 1 turns off the power system. A get/get-next always retuns a 0.

What is upsDisconnect?

This read-write integer allows the UPS backup power system to conserve its battery, where setting the value to 1 turns off the power system, and a get or get-next always returns 0. An administrator uses this to intentionally cut UPS output to preserve battery charge, for instance during extended planned outages where continuous UPS support isn't needed. For example, ahead of a multi-day planned facility power-down, the admin sets this object to 1 to conserve the UPS battery rather than have it discharge supporting an already-idle system.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.1.6.3.1.1.4
snmpwalk -v2c -c public <target> CTRON-COMMON-MIB::upsDisconnect

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.1.6.3.1.1.4.1
snmpget -v2c -c public <target> CTRON-COMMON-MIB::upsDisconnect.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.52.1.6.3.1.1.4.1 i <value>

Start monitoring Cabletron/Enterasys switch/router (shared definitions module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-COMMON-MIB::upsDisconnect OID value, configure state conditions and alerts, and monitor any Cabletron/Enterasys switch/router (shared definitions module) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.1commsDeviceCabletron-MIB
1.3.6.1.4.1.52.1.6subsystemCabletron-MIB
1.3.6.1.4.1.52.1.6.3upsIRM-OIDS
Numeric OIDNameModule
1.3.6.1.4.1.52.1.6.3.1upsVersionCTRON-COMMON-MIB
1.3.6.1.4.1.52.1.6.3.1.1upsRevisionCTRON-COMMON-MIB
1.3.6.1.4.1.52.1.6.3.1.1.4upsDisconnectCTRON-COMMON-MIB