CTATM-CONFIG-MIB :: ctATMPhyRedundTestResult

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCTATM-CONFIG-MIBctATMPhyRedundTestResult

ctATMPhyRedundTestResult

Module: CTATM-CONFIG-MIB

OID (symbolic): CTATM-CONFIG-MIB::ctATMPhyRedundTestResult

OID (numeric): 1.3.6.1.4.1.52.4.1.2.10.1.2.1.1.1.9

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This object returns the status of the last test performed on all the ports. If the test was performed as a result of ctATMPhyRedundPerformTest.immediate, then the value of this object is of the form 1xx. If the test was performed as a result of setting ctATMPhyRedundTestTOD, then the result is of the form 2xx. The meaning of xx is the same in both cases and is explained below:

00 All ports involved in redundancy are good. 01 Primary port (as identified by ctATMPhyRedundPrimaryPort) is bad, but all other non-primary ports are good. 02 Primary port is good, but one or more non-primary ports are bad. 03 Primary port and one or more non-primary ports are bad.

Any other value for this object may be interpreted to mean that no test has been performed on the ports involved in redundancy since system startup.

This object is NOT persistent.

What is ctATMPhyRedundTestResult?

This read-only INTEGER reports the outcome of the last redundancy test, with the hundreds digit distinguishing an immediate test (1xx) from a scheduled test (2xx) and the remaining digits encoding the specific result, such as 00 meaning all ports are good. An admin checks this after a test to see whether the primary and backup ports are actually healthy. For example, a result of 101 (manualPrimaryBadOthersGood) tells the admin an on-demand test found the primary port bad while the other redundant ports tested fine, pointing at that primary port's cabling or hardware.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.1.2.10.1.2.1.1.1.9
snmpwalk -v2c -c public <target> CTATM-CONFIG-MIB::ctATMPhyRedundTestResult

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.1.2.10.1.2.1.1.1.9.1
snmpget -v2c -c public <target> CTATM-CONFIG-MIB::ctATMPhyRedundTestResult.1

Start monitoring Cabletron/Enterasys ATM switch (interface config) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTATM-CONFIG-MIB::ctATMPhyRedundTestResult OID value, configure state conditions and alerts, and monitor any Cabletron/Enterasys ATM switch (interface config) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCTRON-AP3000-MIB
1.3.6.1.4.1.52.4.1ctronCTRON-MIB-NAMES
1.3.6.1.4.1.52.4.1.2ctDataLinkCTRON-MIB-NAMES
1.3.6.1.4.1.52.4.1.2.10ctATMCTRON-MIB-NAMES
1.3.6.1.4.1.52.4.1.2.10.1ctATMConfigCTRON-MIB-NAMES
Numeric OIDNameModule
1.3.6.1.4.1.52.4.1.2.10.1.2ctATMPhysicalRedundancyCTATM-CONFIG-MIB
1.3.6.1.4.1.52.4.1.2.10.1.2.1ctATMPhysicalRedundancyInterfaceCTATM-CONFIG-MIB
1.3.6.1.4.1.52.4.1.2.10.1.2.1.1ctATMPhyRedundTableCTATM-CONFIG-MIB
1.3.6.1.4.1.52.4.1.2.10.1.2.1.1.1ctATMPhyRedundEntryCTATM-CONFIG-MIB
1.3.6.1.4.1.52.4.1.2.10.1.2.1.1.1.9ctATMPhyRedundTestResultCTATM-CONFIG-MIB