All MIBs › CT-DS0ent-MIB › ctDs0ifInNUcastPkts
ctDs0ifInNUcastPkts
Module: CT-DS0ent-MIB
OID (symbolic): CT-DS0ent-MIB::ctDs0ifInNUcastPkts
OID (numeric): 1.3.6.1.4.1.52.4497.20.2.1.12
Node type: OBJECT-TYPE
Type: Counter
Access: read-only
Description: The number of packets, delivered by this sub-layer to a higher (sub-)layer, which were addressed to a multicast or broadcast address at this sub-layer. This object is deprecated in favour of ctDs0ifInMulticastPkts and ctDs0ifInBroadcastPkts.
What is ctDs0ifInNUcastPkts?
This read-only Counter counts packets delivered by this interface's sub-layer to a higher layer that were addressed to a multicast or broadcast address, though it is deprecated in favor of separate multicast and broadcast packet counters. An admin monitoring an older device without those newer counters relies on this combined figure to spot excessive broadcast/multicast traffic on a DS0 channel. For example, an unexpectedly high ctDs0ifInNUcastPkts value on a point-to-point DS0 link, which shouldn't normally see much broadcast traffic, would prompt the admin to investigate a broadcast storm.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4497.20.2.1.12 snmpwalk -v2c -c public <target> CT-DS0ent-MIB::ctDs0ifInNUcastPkts
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4497.20.2.1.12.1 snmpget -v2c -c public <target> CT-DS0ent-MIB::ctDs0ifInNUcastPkts.1
Start monitoring Cabletron Systems equipment (DS0 TDM circuits) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CT-DS0ent-MIB::ctDs0ifInNUcastPkts OID value, configure state conditions and alerts, and monitor any Cabletron Systems equipment (DS0 TDM circuits) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4497 | ctSSA | CT-DARADIUS-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4497.20 | ctDs0Mib | CT-DS0ent-MIB |
| 1.3.6.1.4.1.52.4497.20.2 | ctDs0ifTable | CT-DS0ent-MIB |
| 1.3.6.1.4.1.52.4497.20.2.1 | ctDs0ifEntry | CT-DS0ent-MIB |
| 1.3.6.1.4.1.52.4497.20.2.1.12 | ctDs0ifInNUcastPkts | CT-DS0ent-MIB |