All MIBs › CPS-MIB › upsAdvanceTestDiagnostics
upsAdvanceTestDiagnostics
Module: CPS-MIB
OID (symbolic): CPS-MIB::upsAdvanceTestDiagnostics
OID (numeric): 1.3.6.1.4.1.3808.1.1.1.7.2.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: UPS will do a diagnostic selftest when the variable is set to testDiagnostics(2). It is no effective to set this value to noTestDiagnostics(1).
What is upsAdvanceTestDiagnostics?
This read-write enumerated value, when set to testDiagnostics, makes the UPS perform a diagnostic self-test on demand. An admin uses this to manually trigger a battery test immediately, outside of whatever automatic schedule is configured. For example, an admin sets this to testDiagnostics(2) right after replacing batteries to confirm the new batteries pass a diagnostic check immediately.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3808.1.1.1.7.2.2 snmpwalk -v2c -c public <target> CPS-MIB::upsAdvanceTestDiagnostics
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.3808.1.1.1.7.2.2.1 snmpget -v2c -c public <target> CPS-MIB::upsAdvanceTestDiagnostics.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.3808.1.1.1.7.2.2.1 i <value>
Start monitoring UPS product line (vendor unclear, enterprise OID 3808) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPS-MIB::upsAdvanceTestDiagnostics OID value, configure state conditions and alerts, and monitor any UPS product line (vendor unclear, enterprise OID 3808) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.3808 | cps | CPS-MIB |
| 1.3.6.1.4.1.3808.1 | products | CPS-MIB |
| 1.3.6.1.4.1.3808.1.1 | hardware | CPS-MIB |
| 1.3.6.1.4.1.3808.1.1.1 | ups | CPS-MIB |
| 1.3.6.1.4.1.3808.1.1.1.7 | upsTest | CPS-MIB |
| 1.3.6.1.4.1.3808.1.1.1.7.2 | upsAdvanceTest | CPS-MIB |
| 1.3.6.1.4.1.3808.1.1.1.7.2.2 | upsAdvanceTestDiagnostics | CPS-MIB |