OID (symbolic): CPS-MIB::ePDUOutletConfigMonitoredName
OID (numeric): 1.3.6.1.4.1.3808.1.1.3.3.4.3.1.2
Node type: OBJECT-TYPE
Type: DisplayString
Access: read-write
Description: The name of the Monitored Outlet. The maximum string size is device dependent. An error will be returned if the set request exceeds the max size.
What is ePDUOutletConfigMonitoredName?
This read-write string assigns a name to a specific monitored outlet, with an error returned if the name exceeds the device's maximum size. Admins set this so that per-outlet load alarms are immediately traceable to the equipment plugged into that outlet. Naming the monitored outlet feeding a UPS-backed switch 'Core-Switch-PSU' means a threshold alarm on that outlet's load names the switch, not just an outlet number.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3808.1.1.3.3.4.3.1.2 snmpwalk -v2c -c public <target> CPS-MIB::ePDUOutletConfigMonitoredName
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.3808.1.1.3.3.4.3.1.2.1 snmpget -v2c -c public <target> CPS-MIB::ePDUOutletConfigMonitoredName.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.3808.1.1.3.3.4.3.1.2.1 s <value>
Start monitoring UPS product line (vendor unclear, enterprise OID 3808) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPS-MIB::ePDUOutletConfigMonitoredName OID value, configure state conditions and alerts, and monitor any UPS product line (vendor unclear, enterprise OID 3808) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.3808 | cps | CPS-MIB |
| 1.3.6.1.4.1.3808.1 | products | CPS-MIB |
| 1.3.6.1.4.1.3808.1.1 | hardware | CPS-MIB |
| 1.3.6.1.4.1.3808.1.1.3 | ePDU | CPS-MIB |
| 1.3.6.1.4.1.3808.1.1.3.3 | ePDUOutlet | CPS-MIB |
| 1.3.6.1.4.1.3808.1.1.3.3.4 | ePDUOutletConfig | CPS-MIB |
| 1.3.6.1.4.1.3808.1.1.3.3.4.3 | ePDUOutletConfigMonitoredTable | CPS-MIB |
| 1.3.6.1.4.1.3808.1.1.3.3.4.3.1 | ePDUOutletConfigMonitoredEntry | CPS-MIB |
| 1.3.6.1.4.1.3808.1.1.3.3.4.3.1.2 | ePDUOutletConfigMonitoredName | CPS-MIB |