CPS-MIB :: ePDU2OutletSwitchedInfoPhaseLayout

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCPS-MIBePDU2OutletSwitchedInfoPhaseLayout

ePDU2OutletSwitchedInfoPhaseLayout

Module: CPS-MIB

OID (symbolic): CPS-MIB::ePDU2OutletSwitchedInfoPhaseLayout

OID (numeric): 1.3.6.1.4.1.3808.1.1.6.6.1.3.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This OID describes the phase connections of the referenced outlet as follows: seqPhase1ToNeutral(1) indicates that the outlet is wired from Phase 1 to Neutral. seqPhase2ToNeutral(2) indicates that the outlet is wired from Phase 2 to Neutral. seqPhase3ToNeutral(3) indicates that the outlet is wired from Phase 3 to Neutral. seqPhase1ToPhase2(4) indicates that the outlet is wired from Phase 1 to Phase 2. seqPhase2ToPhase3(5) indicates that the outlet is wired from Phase 2 to Phase 3. seqPhase3ToPhase1(6) indicates that the outlet is wired from Phase 3 to Phase 1.

What is ePDU2OutletSwitchedInfoPhaseLayout?

This read-only integer reports how a given switched outlet is wired relative to the PDU's phases, such as seqPhase1ToNeutral(1) or seqPhase1ToPhase2(4). An admin uses it to know which specific phase or phase pair that individual outlet draws from when balancing equipment across legs. For example, an outlet reporting seqPhase2ToNeutral(2) tells the admin that outlet's load counts against phase 2 specifically, not phase 1 or 3.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3808.1.1.6.6.1.3.1.5
snmpwalk -v2c -c public <target> CPS-MIB::ePDU2OutletSwitchedInfoPhaseLayout

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3808.1.1.6.6.1.3.1.5.1
snmpget -v2c -c public <target> CPS-MIB::ePDU2OutletSwitchedInfoPhaseLayout.1

Start monitoring UPS product line (vendor unclear, enterprise OID 3808) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPS-MIB::ePDU2OutletSwitchedInfoPhaseLayout OID value, configure state conditions and alerts, and monitor any UPS product line (vendor unclear, enterprise OID 3808) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.3808cpsCPS-MIB
1.3.6.1.4.1.3808.1productsCPS-MIB
1.3.6.1.4.1.3808.1.1hardwareCPS-MIB
1.3.6.1.4.1.3808.1.1.6ePDU2CPS-MIB
1.3.6.1.4.1.3808.1.1.6.6ePDU2OutletCPS-MIB
1.3.6.1.4.1.3808.1.1.6.6.1ePDU2OutletSwitchedCPS-MIB
1.3.6.1.4.1.3808.1.1.6.6.1.3ePDU2OutletSwitchedInfoTableCPS-MIB
1.3.6.1.4.1.3808.1.1.6.6.1.3.1ePDU2OutletSwitchedInfoEntryCPS-MIB
1.3.6.1.4.1.3808.1.1.6.6.1.3.1.5ePDU2OutletSwitchedInfoPhaseLayoutCPS-MIB