All MIBs › CPS-MIB › ePDU2OutletMeteredConfigOverloadThreshold
ePDU2OutletMeteredConfigOverloadThreshold
Module: CPS-MIB
OID (symbolic): CPS-MIB::ePDU2OutletMeteredConfigOverloadThreshold
OID (numeric): 1.3.6.1.4.1.3808.1.1.6.6.2.2.1.7
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: User-defined outlet overload current threshold in Watts.
What is ePDU2OutletMeteredConfigOverloadThreshold?
This read-write integer sets the wattage value at which the metered outlet is considered overloaded. Configuring it lets an admin define exactly when the PDU should flag an outlet as drawing too much power for the equipment plugged into it. For instance, an admin managing a rack of servers might lower this threshold on an outlet feeding older, more fragile equipment so an overload condition is flagged sooner.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3808.1.1.6.6.2.2.1.7 snmpwalk -v2c -c public <target> CPS-MIB::ePDU2OutletMeteredConfigOverloadThreshold
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.3808.1.1.6.6.2.2.1.7.1 snmpget -v2c -c public <target> CPS-MIB::ePDU2OutletMeteredConfigOverloadThreshold.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.3808.1.1.6.6.2.2.1.7.1 i <value>
Start monitoring UPS product line (vendor unclear, enterprise OID 3808) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPS-MIB::ePDU2OutletMeteredConfigOverloadThreshold OID value, configure state conditions and alerts, and monitor any UPS product line (vendor unclear, enterprise OID 3808) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.3808 | cps | CPS-MIB |
| 1.3.6.1.4.1.3808.1 | products | CPS-MIB |
| 1.3.6.1.4.1.3808.1.1 | hardware | CPS-MIB |
| 1.3.6.1.4.1.3808.1.1.6 | ePDU2 | CPS-MIB |
| 1.3.6.1.4.1.3808.1.1.6.6 | ePDU2Outlet | CPS-MIB |
| 1.3.6.1.4.1.3808.1.1.6.6.2 | ePDU2OutletMetered | CPS-MIB |
| 1.3.6.1.4.1.3808.1.1.6.6.2.2 | ePDU2OutletMeteredConfigTable | CPS-MIB |
| 1.3.6.1.4.1.3808.1.1.6.6.2.2.1 | ePDU2OutletMeteredConfigEntry | CPS-MIB |
| 1.3.6.1.4.1.3808.1.1.6.6.2.2.1.7 | ePDU2OutletMeteredConfigOverloadThreshold | CPS-MIB |