All MIBs › CPS-MIB › ePDU2BankConfigOverloadRestriction
ePDU2BankConfigOverloadRestriction
Module: CPS-MIB
OID (symbolic): CPS-MIB::ePDU2BankConfigOverloadRestriction
OID (numeric): 1.3.6.1.4.1.3808.1.1.6.5.2.1.4
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: This OID controls the behavior of a Switched Rack PDU bank when an overload condition is possible and additional outlets are requested to be turned on.
Setting this OID to alwaysAllowTurnON (1) will always allow the outlets on the corresponding bank to turn on.
Setting this OID to restrictOnNearOverload (2) will not allow outlets on the corresponding bank to turn on if the ePDU2BankConfigNearOverloadThreshold OID is exceeded.
Setting this OID to restrictOnOverload (3) will not allow outlets on the corresponding bank to turn on if the ePDU2BankConfigOverloadThreshold OID is exceeded.
What is ePDU2BankConfigOverloadRestriction?
This read-write enumeration controls whether a given bank on a chained Rack PDU allows additional outlets to turn on when near or at overload, choosing alwaysAllowTurnON(1), restrictOnNearOverload(2), or restrictOnOverload(3). An admin sets it so outlets scheduled to power on don't push an already-strained bank past a safe threshold. For example, setting this to restrictOnOverload(3) on a bank shared by several appliances blocks any additional outlet on that bank from energizing once it's already overloaded.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3808.1.1.6.5.2.1.4 snmpwalk -v2c -c public <target> CPS-MIB::ePDU2BankConfigOverloadRestriction
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.3808.1.1.6.5.2.1.4.1 snmpget -v2c -c public <target> CPS-MIB::ePDU2BankConfigOverloadRestriction.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.3808.1.1.6.5.2.1.4.1 i <value>
Start monitoring UPS product line (vendor unclear, enterprise OID 3808) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPS-MIB::ePDU2BankConfigOverloadRestriction OID value, configure state conditions and alerts, and monitor any UPS product line (vendor unclear, enterprise OID 3808) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.3808 | cps | CPS-MIB |
| 1.3.6.1.4.1.3808.1 | products | CPS-MIB |
| 1.3.6.1.4.1.3808.1.1 | hardware | CPS-MIB |
| 1.3.6.1.4.1.3808.1.1.6 | ePDU2 | CPS-MIB |
| 1.3.6.1.4.1.3808.1.1.6.5 | ePDU2Bank | CPS-MIB |
| 1.3.6.1.4.1.3808.1.1.6.5.2 | ePDU2BankConfigTable | CPS-MIB |
| 1.3.6.1.4.1.3808.1.1.6.5.2.1 | ePDU2BankConfigEntry | CPS-MIB |
| 1.3.6.1.4.1.3808.1.1.6.5.2.1.4 | ePDU2BankConfigOverloadRestriction | CPS-MIB |