CPQWCRM-MIB :: waterCoolUnitOutputType

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCPQWCRM-MIBwaterCoolUnitOutputType

waterCoolUnitOutputType

Module: CPQWCRM-MIB

OID (symbolic): CPQWCRM-MIB::waterCoolUnitOutputType

OID (numeric): 1.3.6.1.4.1.232.167.2.4.6.2.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Type of output which is connected to water cool unit to output[waterCoolUnitOutputIndex] 1: no output connected 2: output failure 3: value overflow 4: water valve setpoint 5: water valve hysteresis 6: command for manual control 7: Flow Meter Model, 0=SIKA, 1=Chemline 8: minimum fan speed 9: min delta T, used for fan control 10: max delta T, used for fan control 11: specific heat capacity 12: setpoint heatload warning 13: setpoint Water Flow Loss Emergency Door Opening 14: setpoint High Temperature Emergency Door Opening 15: setpoint Condensation Pump Cycles (Warning) 16: setpoint Condensation Pump Running Time (Warning) 17: command for door opening, 0=lock door, 1=unlock door 18: KP parameter for PID controller 19: KI parameter for PID controller 20: KD parameter for PID controller 21: sampling time PID controller

What is waterCoolUnitOutputType?

This read-only enumerated value reports what specific cooling function a given output index controls on the water-cooling unit, including setpoint, hysteresis, manual command, flow-meter model, and other listed functions. It tells an admin exactly what kind of control a particular output index represents before attempting to configure it. For example, a type value describing flow-meter model tells the admin that output actually selects between SIKA and Chemline flow meters, not a simple on/off relay.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.167.2.4.6.2.1.2
snmpwalk -v2c -c public <target> CPQWCRM-MIB::waterCoolUnitOutputType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.167.2.4.6.2.1.2.1
snmpget -v2c -c public <target> CPQWCRM-MIB::waterCoolUnitOutputType.1

Start monitoring Legacy Compaq (HP) rack/console environmental-management hardware with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQWCRM-MIB::waterCoolUnitOutputType OID value, configure state conditions and alerts, and monitor any Legacy Compaq (HP) rack/console environmental-management hardware from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.167cpqWcrmCPQWCRM-MIB
1.3.6.1.4.1.232.167.2cpqWcrmStatusCPQWCRM-MIB
1.3.6.1.4.1.232.167.2.4cpqWcrmStatusSensorWaterCoolUnitCPQWCRM-MIB
1.3.6.1.4.1.232.167.2.4.6cpqWcrmStatusWaterCoolUnitOutputsCPQWCRM-MIB
1.3.6.1.4.1.232.167.2.4.6.2cpqWcrmWaterCoolUnitOutputTableCPQWCRM-MIB
1.3.6.1.4.1.232.167.2.4.6.2.1cpqWcrmWaterCoolUnitOutputEntryCPQWCRM-MIB
1.3.6.1.4.1.232.167.2.4.6.2.1.2waterCoolUnitOutputTypeCPQWCRM-MIB