Description: The alarm that may be sent when this entry is first set to valid.
If the sample type (cpqMeAlarmSampleType) is absoluteValue(1), then the following comparisons are used to generate an event.
If cpqMeAlarmStartupAlarm is equal to risingAlarm(1) or risingOrFallingAlarm(3), then a single event will be generated if the first sample after this entry becomes valid is greater than or equal to this threshold. If cpqMeAlarmStartupAlarm is equal to fallingAlarm(2) or risingOrFallingAlarm(3), then a single event will be generated if the first sample after this entry becomes valid is less than or equal to this threshold.
This object may not be modified if the associated cpqMeAlarmStatus object is equal to valid(1).
What is cpqMeAlarmStartupAlarm?
This read-write enumerated value controls whether an alarm may fire immediately based on the very first sample taken after the entry becomes valid, and if so whether it triggers on a rising, falling, or either-direction comparison. Administrators set this to control whether a newly enabled alarm can trip right away versus only on subsequent threshold crossings. For example, setting this to risingAlarm(1) means the first sample alone can trigger an event if it's already above the rising threshold, rather than waiting for a rising crossing to happen naturally.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.10.2.2.2.1.6 snmpwalk -v2c -c public <target> CPQTHRSH-MIB::cpqMeAlarmStartupAlarm
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.232.10.2.2.2.1.6.1 snmpget -v2c -c public <target> CPQTHRSH-MIB::cpqMeAlarmStartupAlarm.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.232.10.2.2.2.1.6.1 i <value>
Start monitoring HP/Compaq ProLiant server (resource utilization thresholds) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQTHRSH-MIB::cpqMeAlarmStartupAlarm OID value, configure state conditions and alerts, and monitor any HP/Compaq ProLiant server (resource utilization thresholds) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.232 | compaq | COMPAQ-ID-REC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.232.10 | cpqThresholdMgmt | CPQTHRSH-MIB |
| 1.3.6.1.4.1.232.10.2 | cpqMeComponent | CPQTHRSH-MIB |
| 1.3.6.1.4.1.232.10.2.2 | cpqMeAlarm | CPQTHRSH-MIB |
| 1.3.6.1.4.1.232.10.2.2.2 | cpqMeAlarmTable | CPQTHRSH-MIB |
| 1.3.6.1.4.1.232.10.2.2.2.1 | cpqMeAlarmEntry | CPQTHRSH-MIB |
| 1.3.6.1.4.1.232.10.2.2.2.1.6 | cpqMeAlarmStartupAlarm | CPQTHRSH-MIB |