All MIBs › CPQTHRSH-MIB › cpqMeAlarmRisingThreshold
cpqMeAlarmRisingThreshold
Module: CPQTHRSH-MIB
OID (symbolic): CPQTHRSH-MIB::cpqMeAlarmRisingThreshold
OID (numeric): 1.3.6.1.4.1.232.10.2.2.2.1.7
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: A threshold for the sampled object identifier (cpqMeAlarmVariable).
If the sample type (cpqMeAlarmSampleType) is absoluteValue(1), then the following describes the comparison. When the current sampled value is greater than or equal to this threshold, and the value (cpqMeAlarmValue) at the last sampling interval was less than this threshold, a single event will be generated. If cpqMeAlarmStartupAlarm is equal to risingAlarm(1) or risingOrFallingAlarm(3), then a single event will be generated if the first sample after this entry becomes valid is greater than or equal to this threshold. After a rising event is generated, another such event will not be generated until the sampled value falls below this threshold and reaches the falling threshold (cpaMeAlarmFallingThreshold).
If the sample type (cpqMeAlarmSampleType) is deltaValue(2), then the following describes the comparison. When the most recently sampled value minus the previous sampled value is greater than or equal to the threshold (cpqMeAlarmRisingThreshold), and the current alarm value (cpqMeAlarmValue) is less than the threshold value (cpqMeAlarmRisingThreshold) a single event will be generated. After a rising event is generated, another such event will not be generated until the most recently sampled value minus the previous sampled value falls below this threshold (cpqMeAlarmRisingThreshold) and reaches the falling threshold (cpqMeAlarmFallingThreshold).
This object may not be modified if the associated cpqMeAlarmStatus object is equal to valid(1).
What is cpqMeAlarmRisingThreshold?
This read-write integer sets the upper threshold for the sampled variable; for an absolute-value sample type, an event fires when the current sample meets or exceeds this threshold while the previous sample was below it. Administrators use this to define the high-water mark that should trigger an alert, such as a CPU temperature ceiling. For example, setting this to 75 on a temperature variable would generate an event the moment the sampled value crosses from below 75 up to 75 or higher.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.10.2.2.2.1.7 snmpwalk -v2c -c public <target> CPQTHRSH-MIB::cpqMeAlarmRisingThreshold
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.232.10.2.2.2.1.7.1 snmpget -v2c -c public <target> CPQTHRSH-MIB::cpqMeAlarmRisingThreshold.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.232.10.2.2.2.1.7.1 i <value>
Start monitoring HP/Compaq ProLiant server (resource utilization thresholds) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQTHRSH-MIB::cpqMeAlarmRisingThreshold OID value, configure state conditions and alerts, and monitor any HP/Compaq ProLiant server (resource utilization thresholds) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.232 | compaq | COMPAQ-ID-REC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.232.10 | cpqThresholdMgmt | CPQTHRSH-MIB |
| 1.3.6.1.4.1.232.10.2 | cpqMeComponent | CPQTHRSH-MIB |
| 1.3.6.1.4.1.232.10.2.2 | cpqMeAlarm | CPQTHRSH-MIB |
| 1.3.6.1.4.1.232.10.2.2.2 | cpqMeAlarmTable | CPQTHRSH-MIB |
| 1.3.6.1.4.1.232.10.2.2.2.1 | cpqMeAlarmEntry | CPQTHRSH-MIB |
| 1.3.6.1.4.1.232.10.2.2.2.1.7 | cpqMeAlarmRisingThreshold | CPQTHRSH-MIB |