All MIBs › CPQRACK-MIB › cpqRackServerTempSensorIndex
cpqRackServerTempSensorIndex
Module: CPQRACK-MIB
OID (symbolic): CPQRACK-MIB::cpqRackServerTempSensorIndex
OID (numeric): 1.3.6.1.4.1.232.22.2.4.3.1.1.3
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: A number that uniquely specifies this server within the enclosure.
What is cpqRackServerTempSensorIndex?
This read-only INTEGER uniquely identifies a specific server within its enclosure for the purposes of the temperature-sensor table. It is the key that ties a set of sensor readings and thresholds to one particular server bay. For example, server index 3 lets an admin locate exactly which blade bay a reported over-temperature reading originated from.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.22.2.4.3.1.1.3 snmpwalk -v2c -c public <target> CPQRACK-MIB::cpqRackServerTempSensorIndex
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.232.22.2.4.3.1.1.3.1 snmpget -v2c -c public <target> CPQRACK-MIB::cpqRackServerTempSensorIndex.1
Start monitoring HP ProLiant blade server/rack enclosure with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQRACK-MIB::cpqRackServerTempSensorIndex OID value, configure state conditions and alerts, and monitor any HP ProLiant blade server/rack enclosure from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.232 | compaq | COMPAQ-ID-REC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.232.22 | cpqRackInfo | CPQRACK-MIB |
| 1.3.6.1.4.1.232.22.2 | cpqRackComponent | CPQRACK-MIB |
| 1.3.6.1.4.1.232.22.2.4 | cpqRackServer | CPQRACK-MIB |
| 1.3.6.1.4.1.232.22.2.4.3 | cpqRackServerTempSensor | CPQRACK-MIB |
| 1.3.6.1.4.1.232.22.2.4.3.1 | cpqRackServerTempSensorTable | CPQRACK-MIB |
| 1.3.6.1.4.1.232.22.2.4.3.1.1 | cpqRackServerTempSensorEntry | CPQRACK-MIB |
| 1.3.6.1.4.1.232.22.2.4.3.1.1.3 | cpqRackServerTempSensorIndex | CPQRACK-MIB |