All MIBs › CPQRACK-MIB › cpqRackServerTempSensorEnclosureName
cpqRackServerTempSensorEnclosureName
Module: CPQRACK-MIB
OID (symbolic): CPQRACK-MIB::cpqRackServerTempSensorEnclosureName
OID (numeric): 1.3.6.1.4.1.232.22.2.4.3.1.1.5
Node type: OBJECT-TYPE
Type: DisplayString
Access: read-only
Description: The name of the enclosure which contains the server.
The string will be empty if the enclosure does not report the name or if it could not be determined.
What is cpqRackServerTempSensorEnclosureName?
This read-only DisplayString (0-64 chars) reports the name of the enclosure containing this server, empty if the enclosure does not supply one, in the context of temperature reporting. It lets an admin see which physical enclosure a thermal alert originated in without decoding index numbers. For example, an enclosure name of 'Blade-Chassis-South' tells facilities staff exactly which chassis to check for airflow problems.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.22.2.4.3.1.1.5 snmpwalk -v2c -c public <target> CPQRACK-MIB::cpqRackServerTempSensorEnclosureName
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.232.22.2.4.3.1.1.5.1 snmpget -v2c -c public <target> CPQRACK-MIB::cpqRackServerTempSensorEnclosureName.1
Start monitoring HP ProLiant blade server/rack enclosure with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQRACK-MIB::cpqRackServerTempSensorEnclosureName OID value, configure state conditions and alerts, and monitor any HP ProLiant blade server/rack enclosure from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.232 | compaq | COMPAQ-ID-REC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.232.22 | cpqRackInfo | CPQRACK-MIB |
| 1.3.6.1.4.1.232.22.2 | cpqRackComponent | CPQRACK-MIB |
| 1.3.6.1.4.1.232.22.2.4 | cpqRackServer | CPQRACK-MIB |
| 1.3.6.1.4.1.232.22.2.4.3 | cpqRackServerTempSensor | CPQRACK-MIB |
| 1.3.6.1.4.1.232.22.2.4.3.1 | cpqRackServerTempSensorTable | CPQRACK-MIB |
| 1.3.6.1.4.1.232.22.2.4.3.1.1 | cpqRackServerTempSensorEntry | CPQRACK-MIB |
| 1.3.6.1.4.1.232.22.2.4.3.1.1.5 | cpqRackServerTempSensorEnclosureName | CPQRACK-MIB |