CPQRACK-MIB :: cpqRackServerBladeUIDState

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCPQRACK-MIBcpqRackServerBladeUIDState

cpqRackServerBladeUIDState

Module: CPQRACK-MIB

OID (symbolic): CPQRACK-MIB::cpqRackServerBladeUIDState

OID (numeric): 1.3.6.1.4.1.232.22.2.4.1.1.1.26

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The Unit Identifier LED.

This value will be one of the following:

other(1) The state of the LED could not be determined. Setting the LED state is not allowed.

none(2) The LED is not present. Setting LED state is not allowed.

ledOn(3) The LED is present and ON. The LED can be turned off by setting the cpqRackServerBladeUIDState to ledOff(4).

ledOff(4) The LED is present and OFF. The LED can be turned on by setting the cpqRackServerBladeUIDState to ledOn(3).

What is cpqRackServerBladeUIDState?

This read-write INTEGER controls the blade's Unit Identifier LED, with values other, none, ledOn, or ledOff, and the description notes ledOn can be cleared by writing ledOff(4). Technicians use this to make a specific blade physically light up so it can be found in a rack full of identical units. For example, a remote admin sets this OID to ledOn(3) before calling a data-center tech, who then walks the row looking for the blinking blade rather than counting slots.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.22.2.4.1.1.1.26
snmpwalk -v2c -c public <target> CPQRACK-MIB::cpqRackServerBladeUIDState

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.22.2.4.1.1.1.26.1
snmpget -v2c -c public <target> CPQRACK-MIB::cpqRackServerBladeUIDState.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.232.22.2.4.1.1.1.26.1 i <value>

Start monitoring HP ProLiant blade server/rack enclosure with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQRACK-MIB::cpqRackServerBladeUIDState OID value, configure state conditions and alerts, and monitor any HP ProLiant blade server/rack enclosure from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.22cpqRackInfoCPQRACK-MIB
1.3.6.1.4.1.232.22.2cpqRackComponentCPQRACK-MIB
1.3.6.1.4.1.232.22.2.4cpqRackServerCPQRACK-MIB
1.3.6.1.4.1.232.22.2.4.1cpqRackServerBladeCPQRACK-MIB
1.3.6.1.4.1.232.22.2.4.1.1cpqRackServerBladeTableCPQRACK-MIB
1.3.6.1.4.1.232.22.2.4.1.1.1cpqRackServerBladeEntryCPQRACK-MIB
1.3.6.1.4.1.232.22.2.4.1.1.1.26cpqRackServerBladeUIDStateCPQRACK-MIB