CPQRACK-MIB :: cpqRackPowerEnclosureLoadBalanced

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCPQRACK-MIBcpqRackPowerEnclosureLoadBalanced

cpqRackPowerEnclosureLoadBalanced

Module: CPQRACK-MIB

OID (symbolic): CPQRACK-MIB::cpqRackPowerEnclosureLoadBalanced

OID (numeric): 1.3.6.1.4.1.232.22.2.3.3.1.1.6

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This indicates if the power supply enclosure is in a load balanced state.

What is cpqRackPowerEnclosureLoadBalanced?

This read-only INTEGER (other/notLoadBalanced/loadBalanced) reports whether power draw is being spread evenly across the enclosure's multiple power supplies. Operationally, a notLoadBalanced reading after adding a supply suggests a configuration step was missed and one supply is carrying a disproportionate share of the load. For example, after installing a second power supply an admin re-checks this value to confirm it now reads loadBalanced(3) rather than staying on the original single unit.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.22.2.3.3.1.1.6
snmpwalk -v2c -c public <target> CPQRACK-MIB::cpqRackPowerEnclosureLoadBalanced

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.22.2.3.3.1.1.6.1
snmpget -v2c -c public <target> CPQRACK-MIB::cpqRackPowerEnclosureLoadBalanced.1

Start monitoring HP ProLiant blade server/rack enclosure with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQRACK-MIB::cpqRackPowerEnclosureLoadBalanced OID value, configure state conditions and alerts, and monitor any HP ProLiant blade server/rack enclosure from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.22cpqRackInfoCPQRACK-MIB
1.3.6.1.4.1.232.22.2cpqRackComponentCPQRACK-MIB
1.3.6.1.4.1.232.22.2.3cpqRackEnclosureCPQRACK-MIB
1.3.6.1.4.1.232.22.2.3.3cpqRackPowerEnclosureCPQRACK-MIB
1.3.6.1.4.1.232.22.2.3.3.1cpqRackPowerEnclosureTableCPQRACK-MIB
1.3.6.1.4.1.232.22.2.3.3.1.1cpqRackPowerEnclosureEntryCPQRACK-MIB
1.3.6.1.4.1.232.22.2.3.3.1.1.6cpqRackPowerEnclosureLoadBalancedCPQRACK-MIB