Description: The enclosure fan status has been set to degraded. This trap signifies that an enclosure fan has failed but other fans in the redundant fan group are still operating. This may result in overheating of the enclosure. User Action: Replace the fan as soon as possible.
Examples
Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):
snmptrap -v2c -c public <manager> '' CPQRACK-MIB::cpqRackEnclosureFanDegraded snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.232.0.22009
Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):
snmptrapd -f -Lo -c /dev/null authCommunity log public
Example snmptrapd log entry:
zoo11-linux.zoo [UDP: [192.168.30.111]:49881->[192.168.30.10]:162]: DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (359923417) 41 days, 15:47:14.17 SNMPv2-MIB::snmpTrapOID.0 = OID: CPQRACK-MIB::cpqRackEnclosureFanDegraded
Start monitoring HP ProLiant blade server/rack enclosure with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQRACK-MIB::cpqRackEnclosureFanDegraded OID value, configure state conditions and alerts, and monitor any HP ProLiant blade server/rack enclosure from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.232 | compaq | COMPAQ-ID-REC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.232.0.22009 | cpqRackEnclosureFanDegraded | CPQRACK-MIB |