CPQRACK-MIB :: cpqRackCommonEnclosureTempThreshold

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCPQRACK-MIBcpqRackCommonEnclosureTempThreshold

cpqRackCommonEnclosureTempThreshold

Module: CPQRACK-MIB

OID (symbolic): CPQRACK-MIB::cpqRackCommonEnclosureTempThreshold

OID (numeric): 1.3.6.1.4.1.232.22.2.3.1.2.1.7

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This is the threshold temperature sensor setting in degrees celsius. This is the temperature in which the sensor will be considered to be in a tripped state this causing some action to occur depending on the type of the sensor. The action of temperature sensor threshold will be indicated by the cpqRackCommonEnclosureTempType item. If the type is blowout(5), then the temperature sensor will cause the fans to speed up. If the type is caution(9), then the temperature sensor is in a degraded state. If the type is critical(15), then the enclosure will be considered as in a failed state.

If this value cannot be determined by software, then a value of -1 will be returned.

What is cpqRackCommonEnclosureTempThreshold?

This is the threshold temperature, in degrees Celsius, at which a specific sensor is considered tripped, with the resulting action depending on the sensor's configured cpqRackCommonEnclosureTempType, such as causing fans to speed up if the type is blowout. It tells an admin the exact trigger point for that sensor's protective response before it happens. For example, comparing a rising cpqRackCommonEnclosureTempCurrent against its cpqRackCommonEnclosureTempThreshold lets staff anticipate a fan-speed change or alarm before it actually fires.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.22.2.3.1.2.1.7
snmpwalk -v2c -c public <target> CPQRACK-MIB::cpqRackCommonEnclosureTempThreshold

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.22.2.3.1.2.1.7.1
snmpget -v2c -c public <target> CPQRACK-MIB::cpqRackCommonEnclosureTempThreshold.1

Start monitoring HP ProLiant blade server/rack enclosure with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQRACK-MIB::cpqRackCommonEnclosureTempThreshold OID value, configure state conditions and alerts, and monitor any HP ProLiant blade server/rack enclosure from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.22cpqRackInfoCPQRACK-MIB
1.3.6.1.4.1.232.22.2cpqRackComponentCPQRACK-MIB
1.3.6.1.4.1.232.22.2.3cpqRackEnclosureCPQRACK-MIB
1.3.6.1.4.1.232.22.2.3.1cpqRackCommonEnclosureCPQRACK-MIB
1.3.6.1.4.1.232.22.2.3.1.2cpqRackCommonEnclosureTempTableCPQRACK-MIB
1.3.6.1.4.1.232.22.2.3.1.2.1cpqRackCommonEnclosureTempEntryCPQRACK-MIB
1.3.6.1.4.1.232.22.2.3.1.2.1.7cpqRackCommonEnclosureTempThresholdCPQRACK-MIB