CPQRACK-MIB :: cpqRackCommonEnclosureHasPowerSupplies

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCPQRACK-MIBcpqRackCommonEnclosureHasPowerSupplies

cpqRackCommonEnclosureHasPowerSupplies

Module: CPQRACK-MIB

OID (symbolic): CPQRACK-MIB::cpqRackCommonEnclosureHasPowerSupplies

OID (numeric): 1.3.6.1.4.1.232.22.2.3.1.1.1.18

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The enclosure can contain power supplies.

This will be true(2) is the enclosure can house power supplies. The cpqRackEnclosurePowerTable will contain power enclosure specific information.

Match the cpqRackCommonEnclosureSerialNum in this table to the serial number in the cpqRackEnclosurePowerTable to get complete information on the power enclosure.

What is cpqRackCommonEnclosureHasPowerSupplies?

This boolean-style enumerated value indicates whether a specific enclosure contains power supplies, with true(2) meaning the cpqRackEnclosurePowerTable holds further power-specific details, matched by serial number. It tells a management application whether that enclosure is a power-supply-bearing unit worth checking for power redundancy or failure data. For example, a script auditing power redundancy across a rack would only query the power table for enclosures where cpqRackCommonEnclosureHasPowerSupplies reads true(2).

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.22.2.3.1.1.1.18
snmpwalk -v2c -c public <target> CPQRACK-MIB::cpqRackCommonEnclosureHasPowerSupplies

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.22.2.3.1.1.1.18.1
snmpget -v2c -c public <target> CPQRACK-MIB::cpqRackCommonEnclosureHasPowerSupplies.1

Start monitoring HP ProLiant blade server/rack enclosure with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQRACK-MIB::cpqRackCommonEnclosureHasPowerSupplies OID value, configure state conditions and alerts, and monitor any HP ProLiant blade server/rack enclosure from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.22cpqRackInfoCPQRACK-MIB
1.3.6.1.4.1.232.22.2cpqRackComponentCPQRACK-MIB
1.3.6.1.4.1.232.22.2.3cpqRackEnclosureCPQRACK-MIB
1.3.6.1.4.1.232.22.2.3.1cpqRackCommonEnclosureCPQRACK-MIB
1.3.6.1.4.1.232.22.2.3.1.1cpqRackCommonEnclosureTableCPQRACK-MIB
1.3.6.1.4.1.232.22.2.3.1.1.1cpqRackCommonEnclosureEntryCPQRACK-MIB
1.3.6.1.4.1.232.22.2.3.1.1.1.18cpqRackCommonEnclosureHasPowerSuppliesCPQRACK-MIB