CPQRACK-MIB :: cpqRackCommonEnclosureCondition

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCPQRACK-MIBcpqRackCommonEnclosureCondition

cpqRackCommonEnclosureCondition

Module: CPQRACK-MIB

OID (symbolic): CPQRACK-MIB::cpqRackCommonEnclosureCondition

OID (numeric): 1.3.6.1.4.1.232.22.2.3.1.1.1.16

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The overall condition of the enclosure.

This is the aggregate of the temperature sensors, fans, and fuses within the enclosure.

This value will be one of the following:

other(1) No temperature sensors, fans, or fuses in the enclosure or the state could no be determined.

ok(2) All temperature sensors, fans, and fuses are within the normal operating range.

degraded(3) One or more temperature sensors, fans, or fuses are outside of the normal operating range. None are failed.

failed(4) The temperature sensor exceeded the critical threshold value, a required fan has failed, or a fuse has been tripped.

The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.

What is cpqRackCommonEnclosureCondition?

This enumerated value reports the aggregate health of a specific enclosure's temperature sensors, fans, and fuses combined: other (no such components present or state undeterminable), ok, degraded, or failed. It gives an admin a quick per-enclosure health rollup before checking the individual temperature, fan, or fuse tables. For example, seeing cpqRackCommonEnclosureCondition report degraded(3) on one enclosure would prompt an admin to check that enclosure's specific fan and temperature entries to find which component is at fault.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.22.2.3.1.1.1.16
snmpwalk -v2c -c public <target> CPQRACK-MIB::cpqRackCommonEnclosureCondition

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.22.2.3.1.1.1.16.1
snmpget -v2c -c public <target> CPQRACK-MIB::cpqRackCommonEnclosureCondition.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cpqRackCommonEnclosureCondition.1

Start monitoring HP ProLiant blade server/rack enclosure with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQRACK-MIB::cpqRackCommonEnclosureCondition OID value, configure state conditions and alerts, and monitor any HP ProLiant blade server/rack enclosure from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.22cpqRackInfoCPQRACK-MIB
1.3.6.1.4.1.232.22.2cpqRackComponentCPQRACK-MIB
1.3.6.1.4.1.232.22.2.3cpqRackEnclosureCPQRACK-MIB
1.3.6.1.4.1.232.22.2.3.1cpqRackCommonEnclosureCPQRACK-MIB
1.3.6.1.4.1.232.22.2.3.1.1cpqRackCommonEnclosureTableCPQRACK-MIB
1.3.6.1.4.1.232.22.2.3.1.1.1cpqRackCommonEnclosureEntryCPQRACK-MIB
1.3.6.1.4.1.232.22.2.3.1.1.1.16cpqRackCommonEnclosureConditionCPQRACK-MIB