CPQPOWER-MIB :: upsRecepAutoOnDelay

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCPQPOWER-MIBupsRecepAutoOnDelay

upsRecepAutoOnDelay

Module: CPQPOWER-MIB

OID (symbolic): CPQPOWER-MIB::upsRecepAutoOnDelay

OID (numeric): 1.3.6.1.4.1.232.165.3.10.2.1.6

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Seconds delay after the Outlet is signaled to turn On before the Output is Automatically turned ON. A value of -1 means that this Output should never be turned On automatically, but only when specifically commanded to do so. A value of 0 means that the Receptacle should come On immediately at power-up or for an On command.

What is upsRecepAutoOnDelay?

This is the delay, from -1 to 32767 seconds, after an outlet is signaled to turn on before it is automatically switched on, with -1 meaning it must only be turned on by explicit command and 0 meaning it comes on immediately at power-up or on command. It lets an admin stagger which outlets power back up first versus which wait for manual intervention. For example, setting upsRecepAutoOnDelay to -1 on a receptacle feeding sensitive lab equipment ensures it never powers on unattended after an outage.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.165.3.10.2.1.6
snmpwalk -v2c -c public <target> CPQPOWER-MIB::upsRecepAutoOnDelay

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.165.3.10.2.1.6.1
snmpget -v2c -c public <target> CPQPOWER-MIB::upsRecepAutoOnDelay.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.232.165.3.10.2.1.6.1 i <value>

Start monitoring Compaq/HP-managed UPS/PDU power infrastructure with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQPOWER-MIB::upsRecepAutoOnDelay OID value, configure state conditions and alerts, and monitor any Compaq/HP-managed UPS/PDU power infrastructure from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.165cpqPowerCPQPOWER-MIB
1.3.6.1.4.1.232.165.3upsCPQPOWER-MIB
1.3.6.1.4.1.232.165.3.10upsRecepCPQPOWER-MIB
1.3.6.1.4.1.232.165.3.10.2upsRecepTableCPQPOWER-MIB
1.3.6.1.4.1.232.165.3.10.2.1upsRecepEntryCPQPOWER-MIB
1.3.6.1.4.1.232.165.3.10.2.1.6upsRecepAutoOnDelayCPQPOWER-MIB