All MIBs › CPQNIC-MIB › cpqNicIfPhysAdapterCarrierSenseErrors
cpqNicIfPhysAdapterCarrierSenseErrors
Module: CPQNIC-MIB
OID (symbolic): CPQNIC-MIB::cpqNicIfPhysAdapterCarrierSenseErrors
OID (numeric): 1.3.6.1.4.1.232.18.2.3.1.1.28
Node type: OBJECT-TYPE
Type: Counter
Access: read-only
Description: The number of packets transmitted with carrier sense errors: This counter contains the number of times that the carrier sense signal from the physical layer interface was not asserted or was de-asserted during transmission of a packet without collision.
The carrier sense signal is an ongoing activity of a data station to detect whether or not another station is transmitting. Carrier sense errors are detected when a station transmits a frame and does not detect its own signal on the wire.
If you receive carrier sense errors, check the following:
Failing cable: Packet data traveling through shorted or damaged cabling may cause a signal loss. Ensure that your cable is working and plugged in properly.
Segment not grounded properly: Improper grounding of a segment may allow ground-induced noise to interrupt the signal. Ensure that you have properly grounded all segments.
Noisy cable: Interference or noise produced by motors or other devices can interrupt the signals.
Deaf/partially deaf node: A faulty station that cannot hear the activity is considered a deaf node. If you suspect a deaf node, the network interface card should be replaced.
Failing hub, switch, or controller: Repeaters, switches and controllers can disrupt the network signal, transmit erroneous signals on the wire, or ignore incoming packets. Perform the following steps:
1. Swap out the adapter, adapter cable, and adapter attachment point, one at a time. If you find a faulty component, replace it.
2. If none of the items listed above help you isolate the problem, you may need to replace the switch or hub. Use a network analyzer to isolate the problem area.
What is cpqNicIfPhysAdapterCarrierSenseErrors?
This read-only counter tallies packets transmitted where the carrier sense signal from the physical layer was not properly asserted or was de-asserted during transmission without a collision, which the MIB describes as detecting whether another station is transmitting. An admin treats a rising count here as a possible physical-layer or transceiver fault on this adapter. For example, carrier sense errors appearing consistently on one NIC while its link partner reports none would point to a problem specific to this adapter's transceiver.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.18.2.3.1.1.28 snmpwalk -v2c -c public <target> CPQNIC-MIB::cpqNicIfPhysAdapterCarrierSenseErrors
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.232.18.2.3.1.1.28.1 snmpget -v2c -c public <target> CPQNIC-MIB::cpqNicIfPhysAdapterCarrierSenseErrors.1
Start monitoring Compaq/HP ProLiant server (network interface card) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQNIC-MIB::cpqNicIfPhysAdapterCarrierSenseErrors OID value, configure state conditions and alerts, and monitor any Compaq/HP ProLiant server (network interface card) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.232 | compaq | COMPAQ-ID-REC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.232.18 | cpqNic | CPQNIC-MIB |
| 1.3.6.1.4.1.232.18.2 | cpqNicComponent | CPQNIC-MIB |
| 1.3.6.1.4.1.232.18.2.3 | cpqNicIfPhysAdapter | CPQNIC-MIB |
| 1.3.6.1.4.1.232.18.2.3.1 | cpqNicIfPhysAdapterTable | CPQNIC-MIB |
| 1.3.6.1.4.1.232.18.2.3.1.1 | cpqNicIfPhysAdapterEntry | CPQNIC-MIB |
| 1.3.6.1.4.1.232.18.2.3.1.1.28 | cpqNicIfPhysAdapterCarrierSenseErrors | CPQNIC-MIB |