CPQHOST-MIB :: cpqHoSWRunningEventTime

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCPQHOST-MIBcpqHoSWRunningEventTime

cpqHoSWRunningEventTime

Module: CPQHOST-MIB

OID (symbolic): CPQHOST-MIB::cpqHoSWRunningEventTime

OID (numeric): 1.3.6.1.4.1.232.11.2.6.1.1.11

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-only

Description: The system time at which the monitored event, as per cpqHoSWRunningMonitor, last occurred.

 field  octets  contents                  range
 =====  ======  ========                  =====
   1      1-2   year                      0..65536
   2       3    month                     1..12
   3       4    day                       1..31
   4       5    hour                      0..23
   5       6    minute                    0..59
   6       7    second                    0..60
                (use 60 for leap-second)

The hour, minute, and second field will be set to zero (0) if they are not relevant.

What is cpqHoSWRunningEventTime?

This is a 7-octet date/time stamp recording when the monitored event specified by cpqHoSWRunningMonitor last occurred for this process. An administrator uses it to know exactly when a tracked start, stop, or count event happened, essential for correlating it with other logs during an incident review. For example, matching this event time against an application error log timestamp could confirm the process restart coincided with the reported outage.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.11.2.6.1.1.11
snmpwalk -v2c -c public <target> CPQHOST-MIB::cpqHoSWRunningEventTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.11.2.6.1.1.11.1
snmpget -v2c -c public <target> CPQHOST-MIB::cpqHoSWRunningEventTime.1

Start monitoring HP/Compaq ProLiant server (host OS management) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQHOST-MIB::cpqHoSWRunningEventTime OID value, configure state conditions and alerts, and monitor any HP/Compaq ProLiant server (host OS management) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.11cpqHostOsCPQHOST-MIB
1.3.6.1.4.1.232.11.2cpqHoComponentCPQHOST-MIB
1.3.6.1.4.1.232.11.2.6cpqHoSWRunningCPQHOST-MIB
1.3.6.1.4.1.232.11.2.6.1cpqHoSWRunningTableCPQHOST-MIB
1.3.6.1.4.1.232.11.2.6.1.1cpqHoSWRunningEntryCPQHOST-MIB
1.3.6.1.4.1.232.11.2.6.1.1.11cpqHoSWRunningEventTimeCPQHOST-MIB