CPQCR-MIB :: cpqCrEMUBoardTemperatureStatus

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCPQCR-MIBcpqCrEMUBoardTemperatureStatus

cpqCrEMUBoardTemperatureStatus

Module: CPQCR-MIB

OID (symbolic): CPQCR-MIB::cpqCrEMUBoardTemperatureStatus

OID (numeric): 1.3.6.1.4.1.232.141.2.7.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Environmental Monitoring Unit (EMU) Board Temperature status.

The System Board Temperature status as determined by the EMU is:

Not Installed (2) The board temperature can not be detected in the unit.

Normal (3) The board temperature detected by the EMU is normal.

Below Normal (4) The board temperature detected by the EMU is below normal.

Above Normal (5) The board temperature detected by the EMU is above normal.

Far Below Normal (6) The board temperature detected by the EMU is far below normal.

Far Above Normal (7) The board temperature detected by the EMU is far above normal.

Back To Normal (8) The board temperature detected by the EMU has returned to normal.

What is cpqCrEMUBoardTemperatureStatus?

This read-only enumerated value reports the Environmental Monitoring Unit's assessment of the system board temperature as not installed(2), normal(3), below normal(4), or above normal, for the enclosure housing the Clustered RAID hardware. An administrator monitors it as an early indicator of cooling problems affecting the controller board specifically, separate from drive-level or enclosure-level temperature. A shift from normal(3) to an above-normal reading would prompt an admin to check the enclosure's fans before the board overheats.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.141.2.7.1
snmpwalk -v2c -c public <target> CPQCR-MIB::cpqCrEMUBoardTemperatureStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.141.2.7.1.1
snmpget -v2c -c public <target> CPQCR-MIB::cpqCrEMUBoardTemperatureStatus.1

Start monitoring Compaq/HP ProLiant server (component registry) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQCR-MIB::cpqCrEMUBoardTemperatureStatus OID value, configure state conditions and alerts, and monitor any Compaq/HP ProLiant server (component registry) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.141cpqClusteredRAIDCPQCR-MIB
1.3.6.1.4.1.232.141.2cpqCrComponentCPQCR-MIB
1.3.6.1.4.1.232.141.2.7cpqCrEMUCPQCR-MIB
1.3.6.1.4.1.232.141.2.7.1cpqCrEMUBoardTemperatureStatusCPQCR-MIB