All MIBs › CPE-MANAGER › reportedDwnldSrvrBasePath
reportedDwnldSrvrBasePath
Module: CPE-MANAGER
OID (symbolic): CPE-MANAGER::reportedDwnldSrvrBasePath
OID (numeric): 1.3.6.1.4.1.5504.3.1.21.1.2.1.4.1.11
Node type: OBJECT-TYPE
Type: OCTET STRING
Access: read-only
Description: The cpeConfigMgrDownloadBasePath the CPE last received and now reports back to the CO.
What is reportedDwnldSrvrBasePath?
This read-only OCTET STRING (0..32 bytes) is the cpeConfigMgrDownloadBasePath value the CPE last received and now reports back to the CO. An admin compares this against the profile's currently configured base path to confirm the CPE actually picked up a recent path change rather than still using a stale one. For example, after updating cpeConfigMgrDownloadBasePath for a profile, support checks reportedDwnldSrvrBasePath on an attached CPE to verify it has synced to the new value.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5504.3.1.21.1.2.1.4.1.11 snmpwalk -v2c -c public <target> CPE-MANAGER::reportedDwnldSrvrBasePath
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.5504.3.1.21.1.2.1.4.1.11.1 snmpget -v2c -c public <target> CPE-MANAGER::reportedDwnldSrvrBasePath.1
Start monitoring Zhone Technologies CO equipment / Zhone CPE (Zero Touch Configuration) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPE-MANAGER::reportedDwnldSrvrBasePath OID value, configure state conditions and alerts, and monitor any Zhone Technologies CO equipment / Zhone CPE (Zero Touch Configuration) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.5504 | zhone | Zhone |
| 1.3.6.1.4.1.5504.3 | zhoneGeneric | Zhone |
| 1.3.6.1.4.1.5504.3.1 | zhoneSystem | Zhone |
| 1.3.6.1.4.1.5504.3.1.21 | cpeMgr | ZHONE-SYSTEM-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.5504.3.1.21.1 | cpeMgrModule | CPE-MANAGER |
| 1.3.6.1.4.1.5504.3.1.21.1.2 | cpeConfigMgr | CPE-MANAGER |
| 1.3.6.1.4.1.5504.3.1.21.1.2.1 | cpeConfigMgrObjects | CPE-MANAGER |
| 1.3.6.1.4.1.5504.3.1.21.1.2.1.4 | cpeConfigMgrMemberStatusTable | CPE-MANAGER |
| 1.3.6.1.4.1.5504.3.1.21.1.2.1.4.1 | cpeConfigMgrMemberStatusEntry | CPE-MANAGER |
| 1.3.6.1.4.1.5504.3.1.21.1.2.1.4.1.11 | reportedDwnldSrvrBasePath | CPE-MANAGER |