CPE-MANAGER :: cpeCfgMgrClientDwnldSrvrIP

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCPE-MANAGERcpeCfgMgrClientDwnldSrvrIP

cpeCfgMgrClientDwnldSrvrIP

Module: CPE-MANAGER

OID (symbolic): CPE-MANAGER::cpeCfgMgrClientDwnldSrvrIP

OID (numeric): 1.3.6.1.4.1.5504.3.1.21.1.3.1.4.1

Node type: OBJECT-TYPE

Type: IpAddress

Access: read-write

Description: The IP address of the server hosting files for download by CPEs. This will likely be the ZMS server.

What is cpeCfgMgrClientDwnldSrvrIP?

This read-write IpAddress object is the address of the server hosting files for download by this CPE, noted as likely being the ZMS server. An admin can override this per-client if a specific CPE needs to pull files from a different server than the profile default. For example, an operator temporarily redirects cpeCfgMgrClientDwnldSrvrIP for a single test CPE to a staging download server before rolling a firmware change out fleet-wide.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5504.3.1.21.1.3.1.4.1
snmpwalk -v2c -c public <target> CPE-MANAGER::cpeCfgMgrClientDwnldSrvrIP

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5504.3.1.21.1.3.1.4.1.1
snmpget -v2c -c public <target> CPE-MANAGER::cpeCfgMgrClientDwnldSrvrIP.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5504.3.1.21.1.3.1.4.1.1 a <value>

Start monitoring Zhone Technologies CO equipment / Zhone CPE (Zero Touch Configuration) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPE-MANAGER::cpeCfgMgrClientDwnldSrvrIP OID value, configure state conditions and alerts, and monitor any Zhone Technologies CO equipment / Zhone CPE (Zero Touch Configuration) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5504zhoneZhone
1.3.6.1.4.1.5504.3zhoneGenericZhone
1.3.6.1.4.1.5504.3.1zhoneSystemZhone
1.3.6.1.4.1.5504.3.1.21cpeMgrZHONE-SYSTEM-MIB
Numeric OIDNameModule
1.3.6.1.4.1.5504.3.1.21.1cpeMgrModuleCPE-MANAGER
1.3.6.1.4.1.5504.3.1.21.1.3cpeConfigMgrClientCPE-MANAGER
1.3.6.1.4.1.5504.3.1.21.1.3.1cpeCfgMgrClientObjectsCPE-MANAGER
1.3.6.1.4.1.5504.3.1.21.1.3.1.4cpeCfgMgrClientDownloadServerObjectsCPE-MANAGER
1.3.6.1.4.1.5504.3.1.21.1.3.1.4.1cpeCfgMgrClientDwnldSrvrIPCPE-MANAGER