All MIBs › CONTIVITY-TRAPS-V1-MIB › twoDotFiveVA
twoDotFiveVA
Module: CONTIVITY-TRAPS-V1-MIB
OID (symbolic): CONTIVITY-TRAPS-V1-MIB::twoDotFiveVA
OID (numeric): 1.3.6.1.4.1.2505.1.1.12
Node type: OBJECT-TYPE
Type: DisplayString
Access: read-only
Description: Status of 2.5VA power. Possible Values: Alert: Voltage 2.5 VA: Voltage out of range;
This is the voltage supplied to the primary processor. The supplied voltage to the system is not within the the specified range for that particular voltage. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages.
This is a major problem and the box should be looked at by a qualified Nortel representative as soon as possible. Correct operation of the system is not guaranteed while in this state. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages.
What is twoDotFiveVA?
twoDotFiveVA is a DisplayString that alerts when the 2.5VA voltage rail, which the description identifies as supplying the primary processor, goes out of range. Because this rail specifically feeds the primary CPU, an admin seeing this alert combined with erratic primary-CPU behavior can connect the two symptoms to a single root cause. For example, "Alert: Voltage 2.5 VA: Voltage out of range" paired with unexplained primary-CPU resets would lead the admin to suspect the 2.5VA regulator rather than the CPU itself.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2505.1.1.12 snmpwalk -v2c -c public <target> CONTIVITY-TRAPS-V1-MIB::twoDotFiveVA
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2505.1.1.12.1 snmpget -v2c -c public <target> CONTIVITY-TRAPS-V1-MIB::twoDotFiveVA.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> twoDotFiveVA.1
Start monitoring Nortel/Avaya Contivity VPN Router with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CONTIVITY-TRAPS-V1-MIB::twoDotFiveVA OID value, configure state conditions and alerts, and monitor any Nortel/Avaya Contivity VPN Router from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2505 | newoak | NEWOAK-MIB |
| 1.3.6.1.4.1.2505.1 | contivity | NEWOAK-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2505.1.1 | hardwareCESTrapInfo | CONTIVITY-TRAPS-V1-MIB |