All MIBs › CONTIVITY-TRAPS-V1-MIB › fiveVoltsMinus
fiveVoltsMinus
Module: CONTIVITY-TRAPS-V1-MIB
OID (symbolic): CONTIVITY-TRAPS-V1-MIB::fiveVoltsMinus
OID (numeric): 1.3.6.1.4.1.2505.1.1.10
Node type: OBJECT-TYPE
Type: DisplayString
Access: read-only
Description: Status of -5 Volt power. Possible Values: Alert: Voltage 5 V Minus: Voltage out of range;
The supplied voltage to the system is not within the the specified range for that particular voltage. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages.
This is a major problem and the box should be looked at by a qualified Nortel representative as soon as possible. Correct operation of the system is not guaranteed while in this state. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages.
What is fiveVoltsMinus?
fiveVoltsMinus is a DisplayString that alerts when the -5 Volt power rail falls outside its specified range, the negative counterpart to fiveVoltsPositive. Since both positive and negative 5V rails are tracked separately, an admin can tell from which specific rail the voltage anomaly originates when diagnosing a power supply issue. For example, if fiveVoltsMinus alerts but fiveVoltsPositive does not, the admin knows the fault is isolated to the negative supply circuit rather than a general power-supply failure.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2505.1.1.10 snmpwalk -v2c -c public <target> CONTIVITY-TRAPS-V1-MIB::fiveVoltsMinus
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2505.1.1.10.1 snmpget -v2c -c public <target> CONTIVITY-TRAPS-V1-MIB::fiveVoltsMinus.1
Start monitoring Nortel/Avaya Contivity VPN Router with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CONTIVITY-TRAPS-V1-MIB::fiveVoltsMinus OID value, configure state conditions and alerts, and monitor any Nortel/Avaya Contivity VPN Router from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2505 | newoak | NEWOAK-MIB |
| 1.3.6.1.4.1.2505.1 | contivity | NEWOAK-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2505.1.1 | hardwareCESTrapInfo | CONTIVITY-TRAPS-V1-MIB |
| 1.3.6.1.4.1.2505.1.1.10 | fiveVoltsMinus | CONTIVITY-TRAPS-V1-MIB |