CLEARTRAC7-MIB :: pvcIpxConnection

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCLEARTRAC7-MIBpvcIpxConnection

pvcIpxConnection

Module: CLEARTRAC7-MIB

OID (symbolic): CLEARTRAC7-MIB::pvcIpxConnection

OID (numeric): 1.3.6.1.4.1.727.7.2.10.2.1.32

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: IPX connection. Set this parameter to YES if the RFC1490-compatible FRAD at the remote end requires bridge frames. If IPX data it not required, a NO value will prevent the transmission of unnecessary frames from this PVC, thus reducing your network costs.

What is pvcIpxConnection?

This read-write enumerated value (no/yes/not-applicable/not-available) governs whether IPX traffic is carried over this PVC toward an RFC1490-compatible remote FRAD. An admin sets it to no on a PVC that carries no IPX traffic, which avoids sending unnecessary frames and helps reduce network costs. For example, a PVC used solely for IP routing would leave pvcIpxConnection at no(1) since no IPX data needs to cross it.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.727.7.2.10.2.1.32
snmpwalk -v2c -c public <target> CLEARTRAC7-MIB::pvcIpxConnection

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.727.7.2.10.2.1.32.1
snmpget -v2c -c public <target> CLEARTRAC7-MIB::pvcIpxConnection.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.727.7.2.10.2.1.32.1 i <value>

Start monitoring ClearTrac 7 series asset-tracking hardware with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CLEARTRAC7-MIB::pvcIpxConnection OID value, configure state conditions and alerts, and monitor any ClearTrac 7 series asset-tracking hardware from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.727lucentCLEARTRAC7-MIB
1.3.6.1.4.1.727.7cleartrac7CLEARTRAC7-MIB
1.3.6.1.4.1.727.7.2mgmtCLEARTRAC7-MIB
1.3.6.1.4.1.727.7.2.10pvcCLEARTRAC7-MIB
1.3.6.1.4.1.727.7.2.10.2pvcTableCLEARTRAC7-MIB
1.3.6.1.4.1.727.7.2.10.2.1pvcEntryCLEARTRAC7-MIB
1.3.6.1.4.1.727.7.2.10.2.1.32pvcIpxConnectionCLEARTRAC7-MIB