All MIBs › CLEARTRAC7-MIB › ifvceExtendedDigitSrc
ifvceExtendedDigitSrc
Module: CLEARTRAC7-MIB
OID (symbolic): CLEARTRAC7-MIB::ifvceExtendedDigitSrc
OID (numeric): 1.3.6.1.4.1.727.7.2.18.2.1.53
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Specifies the origin of the extended digits that will be forwarded to the remote unit. Available on a port configured with Autodial activation type.
What is ifvceExtendedDigitSrc?
This read-write setting, available on ports configured with autodial activation type, specifies whether extended dial digits forwarded to the remote unit come from a map or from the user. It determines the source of the extra digits appended after the primary speed-dial number, letting either a preconfigured mapping table or the caller's own keypad input supply them. For example, a courtesy phone that lets a caller add an extension after the main autodial number would have this object set to user(2) so digits typed by the caller are what gets forwarded.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.727.7.2.18.2.1.53 snmpwalk -v2c -c public <target> CLEARTRAC7-MIB::ifvceExtendedDigitSrc
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.727.7.2.18.2.1.53.1 snmpget -v2c -c public <target> CLEARTRAC7-MIB::ifvceExtendedDigitSrc.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.727.7.2.18.2.1.53.1 i <value>
Start monitoring ClearTrac 7 series asset-tracking hardware with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CLEARTRAC7-MIB::ifvceExtendedDigitSrc OID value, configure state conditions and alerts, and monitor any ClearTrac 7 series asset-tracking hardware from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.727 | lucent | CLEARTRAC7-MIB |
| 1.3.6.1.4.1.727.7 | cleartrac7 | CLEARTRAC7-MIB |
| 1.3.6.1.4.1.727.7.2 | mgmt | CLEARTRAC7-MIB |
| 1.3.6.1.4.1.727.7.2.18 | ifvce | CLEARTRAC7-MIB |
| 1.3.6.1.4.1.727.7.2.18.2 | ifvceTable | CLEARTRAC7-MIB |
| 1.3.6.1.4.1.727.7.2.18.2.1 | ifvceEntry | CLEARTRAC7-MIB |
| 1.3.6.1.4.1.727.7.2.18.2.1.53 | ifvceExtendedDigitSrc | CLEARTRAC7-MIB |