All MIBs › CLEARTRAC7-MIB › ifvceEnableDtmfOnTime
ifvceEnableDtmfOnTime
Module: CLEARTRAC7-MIB
OID (symbolic): CLEARTRAC7-MIB::ifvceEnableDtmfOnTime
OID (numeric): 1.3.6.1.4.1.727.7.2.18.2.1.55
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: This parameter specifies whether the duration of DTMF ON can be used to filter unwanted DTMF tones during call progress. If DTMF ON-TIME configuration is enabled, the next parameter is also listed.
What is ifvceEnableDtmfOnTime?
This read-write yes/no setting turns on the DTMF ON-time filtering controlled by ifvceDtmfOnTime, and the desc notes that once enabled the ON-time parameter is also presented for configuration. Leaving it disabled means the port accepts any detected DTMF tone regardless of duration, without the minimum-duration filter applied. For example, an administrator troubleshooting false digit detection on a noisy line would set this object to yes(2) and then tune ifvceDtmfOnTime to the desired filtering threshold.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.727.7.2.18.2.1.55 snmpwalk -v2c -c public <target> CLEARTRAC7-MIB::ifvceEnableDtmfOnTime
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.727.7.2.18.2.1.55.1 snmpget -v2c -c public <target> CLEARTRAC7-MIB::ifvceEnableDtmfOnTime.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.727.7.2.18.2.1.55.1 i <value>
Start monitoring ClearTrac 7 series asset-tracking hardware with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CLEARTRAC7-MIB::ifvceEnableDtmfOnTime OID value, configure state conditions and alerts, and monitor any ClearTrac 7 series asset-tracking hardware from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.727 | lucent | CLEARTRAC7-MIB |
| 1.3.6.1.4.1.727.7 | cleartrac7 | CLEARTRAC7-MIB |
| 1.3.6.1.4.1.727.7.2 | mgmt | CLEARTRAC7-MIB |
| 1.3.6.1.4.1.727.7.2.18 | ifvce | CLEARTRAC7-MIB |
| 1.3.6.1.4.1.727.7.2.18.2 | ifvceTable | CLEARTRAC7-MIB |
| 1.3.6.1.4.1.727.7.2.18.2.1 | ifvceEntry | CLEARTRAC7-MIB |
| 1.3.6.1.4.1.727.7.2.18.2.1.55 | ifvceEnableDtmfOnTime | CLEARTRAC7-MIB |