zoneSetNumber

Module: CISCO-ZS-MIB

OID (symbolic): CISCO-ZS-MIB::zoneSetNumber

OID (numeric): 1.3.6.1.4.1.9.9.294.1.1.3

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The number of entries currently present in the zoneSetTable.

What is zoneSetNumber?

This read-only Integer32 (0-8388608) reports the number of entries currently present in the zoneSetTable. Admins use it as a quick sanity check on how many zone sets are defined on a VSAN, useful for detecting unexpected growth or an empty table after a configuration change. For example, an admin who expected a certain number of zone sets after a bulk configuration push would check this object to confirm the count matches expectations.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.294.1.1.3
snmpwalk -v2c -c public <target> CISCO-ZS-MIB::zoneSetNumber

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.294.1.1.3.1
snmpget -v2c -c public <target> CISCO-ZS-MIB::zoneSetNumber.1

Start monitoring Cisco MDS 9148V/9396V Fibre Channel switches (zoning) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-ZS-MIB::zoneSetNumber OID value, configure state conditions and alerts, and monitor any Cisco MDS 9148V/9396V Fibre Channel switches (zoning) from a single console.

How to Use in IPNetwork Monitor

Select a Cisco MDS 9148V (2024) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type zoneSetNumber into the Find box to locate it in the OID tree, then select it and click OK. It reports how many Fibre Channel zone sets are currently configured on this switch. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the count changes unexpectedly, which would indicate an unplanned zoning configuration change. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.294ciscoZsMIBCISCO-ZS-MIB
1.3.6.1.4.1.9.9.294.1ciscoZoningMIBObjectsCISCO-ZS-MIB
1.3.6.1.4.1.9.9.294.1.1zoneConfigurationCISCO-ZS-MIB
1.3.6.1.4.1.9.9.294.1.1.3zoneSetNumberCISCO-ZS-MIB