CISCO-VSAN-MIB :: fcTimerEdtov

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-VSAN-MIBfcTimerEdtov

fcTimerEdtov

Module: CISCO-VSAN-MIB

OID (symbolic): CISCO-VSAN-MIB::fcTimerEdtov

OID (numeric): 1.3.6.1.4.1.9.9.282.1.4.2

Node type: OBJECT-TYPE

Type: CiscoMilliSeconds

Access: read-write

Description: The Error_Detect_Timeout Value used for FxPorts as the timeout value for detecting an error condition. Note that all switches in a fabric should be configured with the same value of this timeout.

Note that value of this object must be less than value of fcTimerDstov.

What is fcTimerEdtov?

This read-write timer sets the Error_Detect_Timeout Value (E_D_TOV), in milliseconds, that FxPorts use to decide when a Fibre Channel error condition has occurred, and it must be smaller than the fabric's fcTimerDstov value. An administrator keeps this consistent across all switches in the fabric so that error detection timing behaves predictably fabric-wide. For example, setting fcTimerEdtov higher than fcTimerDstov on a switch would violate the required ordering between the two timers and could cause unpredictable error handling.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.282.1.4.2
snmpwalk -v2c -c public <target> CISCO-VSAN-MIB::fcTimerEdtov

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.282.1.4.2.1
snmpget -v2c -c public <target> CISCO-VSAN-MIB::fcTimerEdtov.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.9.9.282.1.4.2.1 s <value>

Start monitoring Cisco MDS/Nexus Fibre Channel storage fabric switches (VSAN) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-VSAN-MIB::fcTimerEdtov OID value, configure state conditions and alerts, and monitor any Cisco MDS/Nexus Fibre Channel storage fabric switches (VSAN) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.282ciscoVsanMIBCISCO-VSAN-MIB
1.3.6.1.4.1.9.9.282.1ciscoVsanMIBObjectsCISCO-VSAN-MIB
1.3.6.1.4.1.9.9.282.1.4vsanFcConfigurationCISCO-VSAN-MIB
1.3.6.1.4.1.9.9.282.1.4.2fcTimerEdtovCISCO-VSAN-MIB