CISCO-VSAN-MIB :: fcNetworkDropLatency

MIB Reference — IPNetwork Monitor

All MIBsCISCO-VSAN-MIBfcNetworkDropLatency

fcNetworkDropLatency

Module: CISCO-VSAN-MIB

OID (symbolic): CISCO-VSAN-MIB::fcNetworkDropLatency

OID (numeric): 1.3.6.1.4.1.9.9.282.1.4.5

Node type: OBJECT-TYPE

Type: CiscoMilliSeconds

Access: read-write

Description:

Network latency of this switch. This is the time interval after which the frames are dropped if they are not delivered in the order they were transmitted. Note that fcNetworkLatency is always greater than fcSwitchLatency.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.282.1.4.5
snmpwalk -v2c -c public <target> CISCO-VSAN-MIB::fcNetworkDropLatency

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.282.1.4.5.1
snmpget -v2c -c public <target> CISCO-VSAN-MIB::fcNetworkDropLatency.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.9.9.282.1.4.5.1 s <value>

OID Breakdown

Numeric OIDNameModule
1isoLANART-AGENT
1.3orgBIANCA-BRICK-PPP-MIB
1.3.6dodBIANCA-BRICK-PPP-MIB
1.3.6.1internetBIANCA-BRICK-PPP-MIB
1.3.6.1.4privateBIANCA-BRICK-PPP-MIB
1.3.6.1.4.1enterprisesANIROOT-MIB
1.3.6.1.4.1.9ciscoCISCO-SMI
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.282ciscoVsanMIBCISCO-VSAN-MIB
1.3.6.1.4.1.9.9.282.1ciscoVsanMIBObjectsCISCO-VSAN-MIB
1.3.6.1.4.1.9.9.282.1.4vsanFcConfigurationCISCO-VSAN-MIB
1.3.6.1.4.1.9.9.282.1.4.5fcNetworkDropLatencyCISCO-VSAN-MIB