CISCO-UNIFIED-COMPUTING-VNIC-MIB :: cucsVnicScsiAdminCdnName

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-VNIC-MIBcucsVnicScsiAdminCdnName

cucsVnicScsiAdminCdnName

Module: CISCO-UNIFIED-COMPUTING-VNIC-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicScsiAdminCdnName

OID (numeric): 1.3.6.1.4.1.9.9.719.1.53.33.1.29

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS vnic:Scsi:adminCdnName managed object property

What is cucsVnicScsiAdminCdnName?

This is the administrator-configured Consistent Device Name (CDN) for this vHBA, the name the guest OS will see for this Fibre Channel adapter regardless of its physical placement. An admin sets this so the OS-level device name stays stable and predictable even if the vHBA moves to different hardware, simplifying storage multipathing and scripting inside the guest. For example, an admin might set adminCdnName to "SAN-HBA-Boot" so the OS always labels this vHBA the same way after a service profile is moved to different blade hardware.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.53.33.1.29
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicScsiAdminCdnName

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.53.33.1.29.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicScsiAdminCdnName.1

Start monitoring Cisco UCS blade/rack servers and fabric interconnects (vNIC/vHBA) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicScsiAdminCdnName OID value, configure state conditions and alerts, and monitor any Cisco UCS blade/rack servers and fabric interconnects (vNIC/vHBA) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.53cucsVnicObjectsCISCO-UNIFIED-COMPUTING-VNIC-MIB
1.3.6.1.4.1.9.9.719.1.53.33cucsVnicScsiTableCISCO-UNIFIED-COMPUTING-VNIC-MIB
1.3.6.1.4.1.9.9.719.1.53.33.1cucsVnicScsiEntryCISCO-UNIFIED-COMPUTING-VNIC-MIB
1.3.6.1.4.1.9.9.719.1.53.33.1.29cucsVnicScsiAdminCdnNameCISCO-UNIFIED-COMPUTING-VNIC-MIB