All MIBs › CISCO-UNIFIED-COMPUTING-VNIC-MIB › cucsVnicSanConnTemplSwitchId
cucsVnicSanConnTemplSwitchId
Module: CISCO-UNIFIED-COMPUTING-VNIC-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicSanConnTemplSwitchId
OID (numeric): 1.3.6.1.4.1.9.9.719.1.53.32.1.16
Node type: OBJECT-TYPE
Type: CucsNetworkSwitchId
Access: read-only
Description: Cisco UCS vnic:SanConnTempl:switchId managed object property
What is cucsVnicSanConnTemplSwitchId?
This identifies which fabric interconnect, fabric A or fabric B, this SAN connectivity template pins its generated vHBAs to. This matters directly for SAN redundancy design, since an admin needs vHBAs split across both fabrics for multipathing rather than all landing on one fabric. For example, setting switchId to fabric A on this template, paired with a second template set to fabric B, gives a service profile dual-fabric SAN redundancy.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.53.32.1.16 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicSanConnTemplSwitchId
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.53.32.1.16.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicSanConnTemplSwitchId.1
Start monitoring Cisco UCS blade/rack servers and fabric interconnects (vNIC/vHBA) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicSanConnTemplSwitchId OID value, configure state conditions and alerts, and monitor any Cisco UCS blade/rack servers and fabric interconnects (vNIC/vHBA) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.53 | cucsVnicObjects | CISCO-UNIFIED-COMPUTING-VNIC-MIB |
| 1.3.6.1.4.1.9.9.719.1.53.32 | cucsVnicSanConnTemplTable | CISCO-UNIFIED-COMPUTING-VNIC-MIB |
| 1.3.6.1.4.1.9.9.719.1.53.32.1 | cucsVnicSanConnTemplEntry | CISCO-UNIFIED-COMPUTING-VNIC-MIB |
| 1.3.6.1.4.1.9.9.719.1.53.32.1.16 | cucsVnicSanConnTemplSwitchId | CISCO-UNIFIED-COMPUTING-VNIC-MIB |