CISCO-UNIFIED-COMPUTING-VNIC-MIB :: cucsVnicSanConnTemplSwitchId

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-VNIC-MIBcucsVnicSanConnTemplSwitchId

cucsVnicSanConnTemplSwitchId

Module: CISCO-UNIFIED-COMPUTING-VNIC-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicSanConnTemplSwitchId

OID (numeric): 1.3.6.1.4.1.9.9.719.1.53.32.1.16

Node type: OBJECT-TYPE

Type: CucsNetworkSwitchId

Access: read-only

Description: Cisco UCS vnic:SanConnTempl:switchId managed object property

What is cucsVnicSanConnTemplSwitchId?

This identifies which fabric interconnect, fabric A or fabric B, this SAN connectivity template pins its generated vHBAs to. This matters directly for SAN redundancy design, since an admin needs vHBAs split across both fabrics for multipathing rather than all landing on one fabric. For example, setting switchId to fabric A on this template, paired with a second template set to fabric B, gives a service profile dual-fabric SAN redundancy.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.53.32.1.16
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicSanConnTemplSwitchId

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.53.32.1.16.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicSanConnTemplSwitchId.1

Start monitoring Cisco UCS blade/rack servers and fabric interconnects (vNIC/vHBA) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicSanConnTemplSwitchId OID value, configure state conditions and alerts, and monitor any Cisco UCS blade/rack servers and fabric interconnects (vNIC/vHBA) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.53cucsVnicObjectsCISCO-UNIFIED-COMPUTING-VNIC-MIB
1.3.6.1.4.1.9.9.719.1.53.32cucsVnicSanConnTemplTableCISCO-UNIFIED-COMPUTING-VNIC-MIB
1.3.6.1.4.1.9.9.719.1.53.32.1cucsVnicSanConnTemplEntryCISCO-UNIFIED-COMPUTING-VNIC-MIB
1.3.6.1.4.1.9.9.719.1.53.32.1.16cucsVnicSanConnTemplSwitchIdCISCO-UNIFIED-COMPUTING-VNIC-MIB