All MIBs › CISCO-UNIFIED-COMPUTING-VNIC-MIB › cucsVnicSanConnTemplMaxDataFieldSize
cucsVnicSanConnTemplMaxDataFieldSize
Module: CISCO-UNIFIED-COMPUTING-VNIC-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicSanConnTemplMaxDataFieldSize
OID (numeric): 1.3.6.1.4.1.9.9.719.1.53.32.1.7
Node type: OBJECT-TYPE
Type: Gauge32
Access: read-only
Description: Cisco UCS vnic:SanConnTempl:maxDataFieldSize managed object property
What is cucsVnicSanConnTemplMaxDataFieldSize?
This is the maximum Fibre Channel data field size, in bytes, this SAN connectivity template configures on the vHBAs it generates. An admin cares because a mismatched max data field size between the vHBA and the SAN fabric or storage array can cause degraded FC performance or connectivity issues. For example, increasing this value from 2048 to 2112 bytes on the template applies the larger frame size to every vHBA subsequently created from it.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.53.32.1.7 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicSanConnTemplMaxDataFieldSize
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.53.32.1.7.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicSanConnTemplMaxDataFieldSize.1
Start monitoring Cisco UCS blade/rack servers and fabric interconnects (vNIC/vHBA) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicSanConnTemplMaxDataFieldSize OID value, configure state conditions and alerts, and monitor any Cisco UCS blade/rack servers and fabric interconnects (vNIC/vHBA) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.53 | cucsVnicObjects | CISCO-UNIFIED-COMPUTING-VNIC-MIB |
| 1.3.6.1.4.1.9.9.719.1.53.32 | cucsVnicSanConnTemplTable | CISCO-UNIFIED-COMPUTING-VNIC-MIB |
| 1.3.6.1.4.1.9.9.719.1.53.32.1 | cucsVnicSanConnTemplEntry | CISCO-UNIFIED-COMPUTING-VNIC-MIB |
| 1.3.6.1.4.1.9.9.719.1.53.32.1.7 | cucsVnicSanConnTemplMaxDataFieldSize | CISCO-UNIFIED-COMPUTING-VNIC-MIB |