CISCO-UNIFIED-COMPUTING-VNIC-MIB :: cucsVnicSanConnPolicyFltAggr

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-VNIC-MIBcucsVnicSanConnPolicyFltAggr

cucsVnicSanConnPolicyFltAggr

Module: CISCO-UNIFIED-COMPUTING-VNIC-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicSanConnPolicyFltAggr

OID (numeric): 1.3.6.1.4.1.9.9.719.1.53.57.1.5

Node type: OBJECT-TYPE

Type: Unsigned64

Access: read-only

Description: Cisco UCS vnic:SanConnPolicy:fltAggr managed object property

What is cucsVnicSanConnPolicyFltAggr?

This is the fault-aggregation bitmask UCS Manager maintains for this SAN connectivity policy, rolling up the presence of any faults raised against it or its child objects. An admin can check this value to quickly tell whether anything under this SAN connectivity policy currently has an outstanding fault, without drilling into every vHBA it generated. For example, a non-zero fltAggr on this policy after applying it to several service profiles would prompt the admin to check the individual vHBAs it produced for a configuration issue.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.53.57.1.5
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicSanConnPolicyFltAggr

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.53.57.1.5.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicSanConnPolicyFltAggr.1

Start monitoring Cisco UCS blade/rack servers and fabric interconnects (vNIC/vHBA) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicSanConnPolicyFltAggr OID value, configure state conditions and alerts, and monitor any Cisco UCS blade/rack servers and fabric interconnects (vNIC/vHBA) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.53cucsVnicObjectsCISCO-UNIFIED-COMPUTING-VNIC-MIB
1.3.6.1.4.1.9.9.719.1.53.57cucsVnicSanConnPolicyTableCISCO-UNIFIED-COMPUTING-VNIC-MIB
1.3.6.1.4.1.9.9.719.1.53.57.1cucsVnicSanConnPolicyEntryCISCO-UNIFIED-COMPUTING-VNIC-MIB
1.3.6.1.4.1.9.9.719.1.53.57.1.5cucsVnicSanConnPolicyFltAggrCISCO-UNIFIED-COMPUTING-VNIC-MIB