CISCO-UNIFIED-COMPUTING-VNIC-MIB :: cucsVnicLanConnTemplSwitchId

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-VNIC-MIBcucsVnicLanConnTemplSwitchId

cucsVnicLanConnTemplSwitchId

Module: CISCO-UNIFIED-COMPUTING-VNIC-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicLanConnTemplSwitchId

OID (numeric): 1.3.6.1.4.1.9.9.719.1.53.25.1.17

Node type: OBJECT-TYPE

Type: CucsVnicLanConnTemplSwitchId

Access: read-only

Description: Cisco UCS vnic:LanConnTempl:switchId managed object property

What is cucsVnicLanConnTemplSwitchId?

This OID reports the fabric interconnect side (CucsVnicLanConnTemplSwitchId) that vNICs derived from this template will be pinned to. Setting the fabric side at the template level lets an admin control failover behavior consistently for every vNIC built from this template. An admin building a redundant pair of templates sets this OID to fabric A on one template and fabric B on its paired template.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.53.25.1.17
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicLanConnTemplSwitchId

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.53.25.1.17.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicLanConnTemplSwitchId.1

Start monitoring Cisco UCS blade/rack servers and fabric interconnects (vNIC/vHBA) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicLanConnTemplSwitchId OID value, configure state conditions and alerts, and monitor any Cisco UCS blade/rack servers and fabric interconnects (vNIC/vHBA) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.53cucsVnicObjectsCISCO-UNIFIED-COMPUTING-VNIC-MIB
1.3.6.1.4.1.9.9.719.1.53.25cucsVnicLanConnTemplTableCISCO-UNIFIED-COMPUTING-VNIC-MIB
1.3.6.1.4.1.9.9.719.1.53.25.1cucsVnicLanConnTemplEntryCISCO-UNIFIED-COMPUTING-VNIC-MIB
1.3.6.1.4.1.9.9.719.1.53.25.1.17cucsVnicLanConnTemplSwitchIdCISCO-UNIFIED-COMPUTING-VNIC-MIB