CISCO-UNIFIED-COMPUTING-VNIC-MIB :: cucsVnicIpV6StaticAddrSecDns

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-VNIC-MIBcucsVnicIpV6StaticAddrSecDns

cucsVnicIpV6StaticAddrSecDns

Module: CISCO-UNIFIED-COMPUTING-VNIC-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicIpV6StaticAddrSecDns

OID (numeric): 1.3.6.1.4.1.9.9.719.1.53.67.1.8

Node type: OBJECT-TYPE

Type: InetAddressIPv6

Access: read-only

Description: Cisco UCS vnic:IpV6StaticAddr:secDns managed object property

What is cucsVnicIpV6StaticAddrSecDns?

This OID reports the secondary DNS server address configured on a manually, statically configured IPv6 address on a vNIC (IpV6StaticAddr), used as a fallback if the primary DNS server doesn't respond. An admin cares because relying on a single DNS server is a common single point of failure, and this secondary entry is what keeps name resolution working if the primary goes down. For example, after a DNS server outage caused intermittent iSCSI boot failures, an admin would check whether this secDns value was even populated as a fallback.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.53.67.1.8
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicIpV6StaticAddrSecDns

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.53.67.1.8.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicIpV6StaticAddrSecDns.1

Start monitoring Cisco UCS blade/rack servers and fabric interconnects (vNIC/vHBA) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicIpV6StaticAddrSecDns OID value, configure state conditions and alerts, and monitor any Cisco UCS blade/rack servers and fabric interconnects (vNIC/vHBA) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.53cucsVnicObjectsCISCO-UNIFIED-COMPUTING-VNIC-MIB
1.3.6.1.4.1.9.9.719.1.53.67cucsVnicIpV6StaticAddrTableCISCO-UNIFIED-COMPUTING-VNIC-MIB
1.3.6.1.4.1.9.9.719.1.53.67.1cucsVnicIpV6StaticAddrEntryCISCO-UNIFIED-COMPUTING-VNIC-MIB
1.3.6.1.4.1.9.9.719.1.53.67.1.8cucsVnicIpV6StaticAddrSecDnsCISCO-UNIFIED-COMPUTING-VNIC-MIB