CISCO-UNIFIED-COMPUTING-VNIC-MIB :: cucsVnicFcRedundancyPairType

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-VNIC-MIBcucsVnicFcRedundancyPairType

cucsVnicFcRedundancyPairType

Module: CISCO-UNIFIED-COMPUTING-VNIC-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicFcRedundancyPairType

OID (numeric): 1.3.6.1.4.1.9.9.719.1.53.11.1.43

Node type: OBJECT-TYPE

Type: CucsVnicRedundancyPairType

Access: read-only

Description: Cisco UCS vnic:Fc:redundancyPairType managed object property

What is cucsVnicFcRedundancyPairType?

This OID reports the redundancy pairing type of a Fibre Channel vNIC, using the CucsVnicRedundancyPairType enumeration to say whether this object is the primary, secondary, or not part of a redundant pair. An admin uses this to confirm a high-availability design is actually wired up as intended, rather than having two vNICs that were both meant to be redundant partners but aren't actually paired. For example, if a server's storage connectivity fails over unexpectedly, an admin checks this field on the Fibre Channel vNIC to confirm its redundancy role matches what the HA design called for.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.53.11.1.43
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicFcRedundancyPairType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.53.11.1.43.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicFcRedundancyPairType.1

Start monitoring Cisco UCS blade/rack servers and fabric interconnects (vNIC/vHBA) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicFcRedundancyPairType OID value, configure state conditions and alerts, and monitor any Cisco UCS blade/rack servers and fabric interconnects (vNIC/vHBA) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.53cucsVnicObjectsCISCO-UNIFIED-COMPUTING-VNIC-MIB
1.3.6.1.4.1.9.9.719.1.53.11cucsVnicFcTableCISCO-UNIFIED-COMPUTING-VNIC-MIB
1.3.6.1.4.1.9.9.719.1.53.11.1cucsVnicFcEntryCISCO-UNIFIED-COMPUTING-VNIC-MIB
1.3.6.1.4.1.9.9.719.1.53.11.1.43cucsVnicFcRedundancyPairTypeCISCO-UNIFIED-COMPUTING-VNIC-MIB